24
English
Code
Air leaks
....................................................................................................................................
1
Air leaks in air tank or at air tank welds
....................................................................................
2
Air leaks between head and valve plate
....................................................................................
3
Air leaks from safety valve
.........................................................................................................
4
Compressor is not supplying enough air to operate accessories
............................................
1, 5, 6, 7, 9, 10
Restricted air intake
...................................................................................................................
9
Oil in discharge air
.....................................................................................................................
9, 19, 31
Knocking Noise
.........................................................................................................................
4, 10, 11, 12, 13, 14
Excessive belt wear
...................................................................................................................
10, 11, 14, 15
Squealing sound
........................................................................................................................
10
Moisture in pump crankcase
.....................................................................................................
1, 3, 8, 17, 18, 19, 20, 21, 22
Excessive current draw
.............................................................................................................
14, 26, 27
Compressor won’t start in cold temperatures
..........................................................................
17, 34, 35
Pressure reading on the regulated pressure gauge drops when and accessory is used
.........
23
Regulator knob has continuous air leak
....................................................................................
24
Regulator will not shut off air outlet
..........................................................................................
24
Air tank pressure will not build
..................................................................................................
25
Compressor stalls
......................................................................................................................
28, 29, 30
Overheating
...............................................................................................................................
27, 32, 33