Dewalt DXCMV7518075 Instruction Manual - Page 14

How to Use Your Unit Fig 3

Page 14 highlights

English AIR FLOW FEEDER LINES SLOPE WITH AIR FLOW AIR FLOW MAIN DISTRIBUTION AIR LINES Slope pipe in di rection of air o w. Water condensate ows along bottom of pipe to drain legs, preventing it f rom entering feeder lines. .01 MICRON FI LTER 5 MICRON FI LTER SPR AY GUN REGUL ATOR BALL FI LTER FI LTER / MOISTURE TRAP FOR BEST PERFORMANCE the distance between the comp ressor and the moistu re trap should be as long as possible DRAIN VALVE TYPICAL COMPRESSED AIR DISTRIBUTION SYSTEM RISK OF BURSTING. ALWAYS USE METAL PIPING AND FITTINGS. AIR USAGE LINES DIR T LEGS DRAIN VALVES FLEXIBLE COUPLING FI LTER / MOISTURE TRAP DRAIN LEGS DRAIN VALVES REGUL ATOR LUBRIC ATOR AIR TOOL AIR COMPRESSOR GLOBE VALVE / AIR DISCHARGE VALVE DRAIN VALVE How to Use Your Unit (Fig 3) How to Stop: Set the Auto/Off switch to "Off". Before Starting WARNING: Do not operate this unit until you read this instruction manual for safety, operation and maintenance instructions. Break-in Procedure NOTICE: Risk of property damage. Serious damage may result if the following break-in instructions are not closely followed. This procedure is required before the air compressor is put into service and when the check valve or a complete compressor pump has been replaced. 1. Make sure the Auto/Off switch is in the "Off" position. 2. Check oil level in pump. See Oil paragraph in the Maintenance section for instructions. 3. Recheck all wiring. Make sure wires are secure at all terminals connections. Make sure all contacts move freely and are not obstructed. 4. Open the drain valve (counterclockwise) fully to permit air to escape and prevent air pressure build up in the air tank during the break-in period. 5. Move the Auto/Off switch to "Auto" position. The compressor will start. 6. Run the compressor for 30 minutes. Make sure the drain valve and all air lines are open so there is only a minimal air pressure build-up in tank. NOTE: After about 30 minutes, If the unit does not operate properly, SHUT DOWN IMMEDIATELY, and contact Product Service. 7. Check all air line fittings and connections/piping for air leaks by applying a soap solution. Correct if necessary. NOTE: Minor leaks can cause the air compressor to overwork, resulting in premature breakdown or inadequate performance. 8. Check for excessive vibration. Readjust or shim air compressor feet, if necessary. 14

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92

14
English
SPR AY
GUN
AIR
TOOL
DRAIN
LEGS
FI LTER /
MOISTURE
TRAP
DIRT
LEGS
DRAIN
VALVES
DRAIN
VALVE
LUBRIC
ATOR
REGUL
ATOR
GLOBE
VALVE /
AIR DISCHARGE
VALVE
MAIN DISTRIBUTION AIR LINES
Slope pipe in di
rection of air flo
w.
Water condensate flows along
bottom of pipe to drain legs,
preventing it f
rom entering feeder
lines.
REGUL
ATOR
BALL
FI LTER
FLEXIBLE
COUPLING
DRAIN
VALVE
TYPICAL
COMPRESSED AIR
DISTRIBUTION
SYSTEM
AIR FLOW
AIR FLOW
FEEDER LINES SLOPE
WITH AIR FLOW
AIR USAGE
LINES
AIR
COMPRESSOR
FI LTER /
MOISTURE
TRAP
FOR BEST PERFORMANCE
the distance between the
comp ressor and the
moistu re trap should be as
long as possible
DRAIN
VALVES
5 MICRON
FI LTER
.01 MICRON
FI LTER
RISK OF BURSTING. ALWAYS USE
METAL PIPING AND FITTINGS.
How to Use Your Unit (Fig 3)
How to Stop:
Set the Auto/Off switch to “Off”.
Before Starting
WARNING:
Do not operate this unit until you read this instruction
manual for safety, operation and maintenance instructions.
Break-in Procedure
NOTICE:
Risk of property damage. Serious damage may result if
the following break-in instructions are not closely followed.
This procedure is required
before
the air compressor is put into
service and when the check valve or a complete compressor pump
has been replaced.
1.
Make sure the Auto/Off switch is in the “Off” position.
2.
Check oil level in pump. See
Oil
paragraph in the
Maintenance
section for instructions.
3.
Recheck all wiring. Make sure wires are secure at all terminals
connections. Make sure all contacts move freely and are not
obstructed.
4.
Open the drain valve (counterclockwise) fully to permit air to
escape and prevent air pressure build up in the air tank during
the break-in period.
5.
Move the Auto/Off switch to “Auto” position. The compressor
will start.
6.
Run the compressor for 30 minutes. Make sure the drain valve
and all air lines are open so there is only a minimal air pressure
build-up in tank.
NOTE:
After about 30 minutes, If the unit does not operate
properly, SHUT DOWN IMMEDIATELY, and contact
Product Service.
7.
Check all air line fittings and connections/piping for air leaks
by applying a soap solution. Correct if necessary.
NOTE:
Minor
leaks can cause the air compressor to overwork, resulting in
premature breakdown or inadequate performance.
8.
Check for excessive vibration. Readjust or shim air compressor
feet, if necessary.