Gas Cooktop Installation Over 30" Single Electric Wall Oven For all approved gas cooktop models, a minimum height opening of 6-1/2" (from top of counter) required in right cabinet side panel and/or filler panel, to route gas and electric hookups. (Refer to Gas Cooktop Utility Hookup Diagram) Side filler panels necessary to isolate oven from adjoining cabinets. Panel height may need to be modified to accommodate the depth of approved gas cooktop models 120V/60Hz grounded outlet, for gas cooktop Cooktop cutout** Approx. 3" 240 /208V Junction box for wall oven 24" min.* 28 1/2" min. 29" max. Cooktop 18" max. Countertop Manifold pipe Flare union 61/2" min. 5" Flexible connector Pressure regulator 4" Gas Cooktop Utility Hookup Flare union 120V/60Hz grounded outlet Cabinet sides and/or filler panel Manual shutoff valve (Must be accessible) Oven cutout 36" min. 28 1/4" min. 28 7/8" max. Side View Cooktop Wall Oven 24" min. cutout depth 4-1/2" maximum height allowed from oven base to floor if cooktop is installed directly over wall oven. (5" maximum height allowed with no cooktop.) Install 3/4" full plywood base on 2 runners, flush with toe plate, capable of supporting 200 lbs. Unit will overlap cutout (minimum) edges by 1" To route armoured cable to junction box through left cabinet side panel and/or filler panel, cut minimum 4" x 4" opening in wood base and runner *Critical dimension - MUST be applied **For cooktop cutout dimensions refer to model-specific product installation instructions on the web Gas Cooktop Installation Over 30" Single Electric Wall Oven Specifications Single Wall Ovens are approved to be used beneath Electrolux ICON™ gas cooktop models E46GC66ESS, E36GC65ESS, E36GC70FSS and E30GC70FSS (gas cooktop models NOT approved for use in this installation are E36GC75ESS, E46GC67ESS, E36GC76EPS, E48GC76EPS and E30GC64ESS.) For detailed Gas Cooktop installation specifications, refer to product-specific section, pages 18-35. • Side filler panels necessary to isolate oven from adjoining cabinets. Panel height may need to be modified to accommodate the depth of approved gas cooktop models. • Minimum height opening of 6-1/2" (from top of counter) required in right cabinet side panel or filler panel, to route gas and electric hookups. • Allow 4-1/2" maximum height from oven base to floor, if cooktop is installed directly over wall oven. 30" Single Electric Wall Oven Under-Counter Installation Specifications • Product Weights - (E30EW75EPS) 177 Lbs. / (E30EW75ESS) 168 Lbs. • Single phase 3- or 4-wire cable, 120 / 240 or 120 / 208 Volt, 60 Hertz AC only electrical supply with ground required on separate circuit fused on both sides of line. • Connected Load (kW Rating) - 240 / 208 Volts = 4.0 / 3.0 kW • Amps @ 240 / 208 Volts = 16.6 / 14.4 Amps • Always consult local and /or national electric codes. • Minimum 23-1/4" clearance for oven door depth when open. • Minimum 24" deep, cutout dimension is critical for proper installation. If oven's face profile does not fit flush against cabinet, or if noise is heard from oven's convection system, verify dimension. • Full oven base of solid plywood or similar material required, capable of supporting 200 Lbs. Install over two runners and flush with toe plate. • Base must be level and cabinet front must be square. • Side filler panels necessary to isolate oven from adjoining cabinets. • Allow 5" maximum height from oven base to floor, if NO cooktop is installed directly over wall oven. Note: Refer to Product Installation Guides for detailed instructions on the web at electroluxusa.com.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8

For all approved gas cooktop models, a minimum
height opening of 6-1/2" (from top of counter) required
in right cabinet side panel and/or filler panel, to route
gas and electric hookups. (Refer to Gas Cooktop
Utility Hookup Diagram)
Oven cutout
120V/60Hz
grounded
outlet, for
gas cooktop
Cooktop
cutout**
28
1
/
4
" min.
28
7
/
8
" max.
240/208V
Junction box
for wall oven
Approx. 3"
24" min.
cutout depth
To route armoured cable to junction box through left cabinet side panel
and/or filler panel, cut minimum 4" x 4" opening in wood base and runner
*Critical dimension – MUST be applied
**For cooktop cutout dimensions refer to model-specific
product installation instructions on the web
5"
6
1
/
2
"
min.
Pressure regulator
Manual shutoff valve
(Must be accessible)
Cabinet sides
and/or filler panel
Flare union
Manifold
pipe
Flexible connector
Flare
union
4"
Countertop
18"max.
120V/60Hz
grounded outlet
Cooktop
Gas
Cooktop
Utility
Hookup
Side filler panels necessary to isolate oven from
adjoining cabinets. Panel height may need to
be modified to accommodate the depth of approved
gas cooktop models
4-1/2" maximum height allowed
from oven base to floor if cooktop
is installed directly over wall oven.
(5" maximum height allowed
with no cooktop.)
Side View
Cooktop
Wall Oven
36"
min.
Unit will overlap cutout (minimum) edges by 1"
Install
3
/
4
" full plywood base on 2 runners, flush
with toe plate, capable of supporting 200 lbs.
24"min.*
28
1
/
2
"min.
29"max.
Gas Cooktop Installation Over
30" Single Electric Wall Oven Specifications
Single Wall Ovens are approved to be used beneath Electrolux
ICON
gas cooktop models E46GC66ESS, E36GC65ESS,
E36GC70FSS and E30GC70FSS (gas cooktop models NOT
approved for use in this installation are E36GC75ESS,
E46GC67ESS, E36GC76EPS, E48GC76EPS and E30GC64ESS.)
For detailed Gas Cooktop installation specifications, refer to
product-specific section, pages 18-35.
Side filler panels necessary to isolate oven from adjoining
cabinets. Panel height may need to be modified to
accommodate the depth of approved gas cooktop models.
Minimum height opening of 6-1/2" (from top of counter)
required in right cabinet side panel or filler panel, to route gas
and electric hookups.
Allow 4-1/2" maximum height from oven base to floor, if
cooktop is installed directly over wall oven.
30" Single Electric Wall Oven Under-Counter
Installation Specifications
Product Weights –
(E30EW75EPS) 177 Lbs. / (E30EW75ESS) 168 Lbs.
Single phase 3- or 4-wire cable, 120/240 or 120/208 Volt,
60 Hertz AC only electrical supply with ground required on
separate circuit fused on both sides of line.
Connected Load (kW Rating) – 240/208 Volts = 4.0/3.0 kW
Amps @ 240/208 Volts =16.6/14.4 Amps
Always consult local and/or national electric codes.
Minimum 23-1/4" clearance for oven door depth when open.
Minimum 24" deep, cutout dimension is critical for proper install-
ation. If oven’s face profile does not fit flush against cabinet, or if
noise is heard from oven’s convection system, verify dimension.
Full oven base of solid plywood or similar material required,
capable of supporting 200 Lbs. Install over two runners and
flush with toe plate.
Base must be level and cabinet front must be square.
Side filler panels necessary to isolate oven from adjoining cabinets.
Allow 5" maximum height from oven base to floor, if NO cooktop
is installed directly over wall oven.
Note: Refer to Product Installation Guides for detailed instructions
on the web at electroluxusa.com.
Gas Cooktop Installation Over