Electrolux EDW5505E Service Manual - Page 29
WT60 - 65 USPH, Prog. 006
View all Electrolux EDW5505E manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 29 highlights
Electrolux EFS - Dishwashing Systems Platform Electrolux Professional Electronic Dishwasher SERVICE MANUAL WT60 - 65 USPH Prog. 006 1. Switch OFF and then switch ON the machine. 2. CFG Enter into CFG parameter family and set the following parameters: tYP boi doo dFL trc b_t btF LES UI rE ALr 0 0 1 1 0 1 75 0 9 0 1 Hood Type like working cycles. Atmospheric boiler. Manual Hood. Default values for Hood Type models. (for this appliance SOFT START is NOT possible). Tank heater works only if boiler temperature reached. Enable filling tank by means of rinsing cycles. Detergent level switches not enabled. Select user interface hood type model (up to version 3.11 set to 1). Regeneration cycle disabled. Alarms enabled. 3. Switch OFF and then switch ON the machine. 4. Modify Factory parameters: FAC Factory parameters family bt°C 78 Boiler Temperature Threshold. 5. Modify the cycle parameters: CY1 Enter into Cycle 1 parameters family. ri1 dr1 25 Rinse Phase Duration [s] 25 Drain [s] CY2 Enter into Cycle 2 parameters family. ri2 dr2 25 Rinse Phase Duration [s] 25 Drain [s] CY3 Enter into Cycle 3 parameters family. ri3 25 Rinse Phase Duration [s] dr3 25 Drain [s] 6. Select Fahrenheit : dPA Enter into Dishwashing parameter family. C F 1 Select Fahrenheit degrees. 6. Switch OFF and then switch ON the machine. DOC. NO. 5956.446.06 ©Copyright 2005 by Electrolux Professional P.29/88