Electrolux EDW5505E Service Manual - Page 65
Prog. 041
View all Electrolux EDW5505E manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 65 highlights
Electrolux EFS - Dishwashing Systems Platform Electrolux Professional Electronic Dishwasher SERVICE MANUAL LU7A Prog. 041 1. Switch OFF and then switch ON the machine. 2. CFG Enter into CFG parameter family and set the following parameters. tYP boi doo dFL trc b_t btF LES UI rE ALr 0 0 2 1 3 1 75 0 9 0 1 Hood Type like working cycles. Atmospheric boiler. Front loading. Default values for Hood Type models. SLOW SOFT START ENABLED Tank heater works only if boiler temperature reached. Enable filling tank by means of rinsing cycles. Detergent level switches not enabled. Select user interface hood type model (up to version 3.11 set to 1). Regeneration cycle disabled. Alarms enabled. 3. Switch OFF and then switch ON the machine. 4. Modify Factory parameters: FAC Enter into FAC parameter family and change boiler threshold. bt°C bAJ 82 0 Boiler Temperature Threshold. Boiler Temperature Adjust. bSt 1 Booster Function. 5. Modify the cycle parameters: CY2 Cycle 2 parameters family. Ln2 Sh2 1 10 Long Wash Phase [min] Short Wash Phase [s] CY3 Cycle 3 parameters family. Ln3 4 Long Wash Phase [min] 6. Switch OFF and then switch ON the machine. DOC. NO. 5956.446.06 ©Copyright 2005 by Electrolux Professional P.65/88