Cmearance, requirements

Page 8 highlights

installation Requirements Cmearance requirements iNSTALLATiON iN A RECESS OR CLOSET 1. A dryer installed in a bedroom, bathroom, recess or closet, MUST be exhausted outdoors. 2. No other fuel burning appliance shall be installed in the same closet as the gas dryer. 3. Your dryer needs the space around it for proper ventilation. DO NOT install your dryer in a closet with a solid door. . Closet door ventilation required: A minimum of 120 square inches (774.2 cm 2)of opening, equally divided at the top and bottom of the door, is required. Openings should be located 3 inches (7.6 cm) from bottom and top of door. Openings are required to be unobstructed when a door is installed. A Iouvered door with equivalent air openings for the full length of the door is acceptable. MINIMUM INSTALLATION CLEARANCES -Inches (cm) SIDES REAR TOP FRONT Alcove 0" (0 cm) 0" (0 cm)* 0" (0 cm) n/a Under- Counter 0" (0 cm) 0" (0 cm)* 0" (0 cm) n/a Closet 0" (0 cm) 0" (0 cm)* 0" (0 cm) 1" (2.54 cm) For other than straight back venting, a quick-turn 90 ° dryer vent elbow must be installed to achieve 0" (0 cm) r (Ooc"m) t 60 sq. in. (387.1cm 2} f 60 sq. in. (387.1cm 2)

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26

installation
Requirements
Cmearance
requirements
iNSTALLATiON
iN
A RECESS
OR
CLOSET
1. A dryer installed
in a bedroom,
bathroom,
recess or closet,
MUST be exhausted
outdoors.
2.
No other fuel burning
appliance
shall be
installed
in the same closet as the gas dryer.
3. Your dryer needs the space around
it for proper
ventilation.
DO NOT install your dryer
in a closet with a solid
door.
.
Closet
door ventilation
required: A minimum
of 120 square inches (774.2 cm 2)of opening,
equally divided at the top and bottom
of the
door, is required. Openings
should be located
3 inches (7.6 cm) from bottom and top of door.
Openings
are required to be unobstructed
when a door is installed. A Iouvered door with
equivalent
air openings for the full length of the
door is acceptable.
60 sq.
in.
(387.1cm
2}
f
60 sq.
in.
(387.1cm
2)
MINIMUM
INSTALLATION
CLEARANCES
-Inches
(cm)
SIDES
REAR
TOP
FRONT
Alcove
0" (0 cm)
0" (0 cm)*
0" (0 cm)
n/a
Under-
0" (0 cm)
0" (0 cm)*
0" (0 cm)
n/a
Counter
Closet
0" (0 cm)
0" (0 cm)*
0" (0 cm)
1" (2.54 cm)
For other than straight back venting,
a quick-turn
90°
dryer vent elbow
must be installed to achieve
0" (0 cm)
r
o"
t
(Ocm)