EMERSON QUICK START GUIDE Wiring Ceiling Fan (page 11) 1. Connect the green grounding lead from the hanger ball and the green grounding lead from the hanger bracket to the grounding conductor of supply (this may be a bare wire or wire with green colored insulation). Securely connect wires with wire connectors supplied. NOTE: If you are using an Emerson Light Fixture with your fan, see Light Fixture Owner's Manual for wiring. 2. Securely connect the fan motor white wire to the supply white (neutral) wire using wire connector supplied. Securely connect the fan motor black wire to the supply black (hot) wire using wire connector supplied. After connections have been made, turn leads upward and carefully push leads into the outlet box, with the white and green leads on one side of the outlet box and the black leads on the other side of the outlet box. GROUND WIRE LISTED WIRE CONNECTOR (3) BLACK FAN WIRE WHITE SUPPLY (NEUTRAL) GREEN WIRE (GROUND) FROM HANGER BRACKET WHITE FAN WIRE GREEN WIRE BLACK SUPPLY (GROUND) FROM (HOT) HANGER BALL NOTE: CEILING COVER OMITTED FOR CLARITY. Installation of Ceiling Cover (page 11) Programming Receiver (page 12) 1. Separate the grounded white neutral and green wires on one side of the outlet box from the ungrounded black and blue wires on the other side of the outlet box 2. Insert the grounded green and white wires into one side of the outlet box, and the ungrounded black and blue wires into the other side of 4. Install the ceiling cover onto the outlet box. the hanger bracket. using the 3. Screw the two threaded studs studs, lock washers and into the tapped holes in the knurled nuts supplied. hanger bracket. Your wall control has code switches which must be set in one of 32 possible code combinations. The five levers (numbered 1, 2, 3, 4, and 5) on the switches are factory-set in the ON (up) position. Change the switch settings as follows: 1. Slide the five switch levers in the wall control to your choice of ON (up) or down positions. Use a ball-point pen or small screwdriver and slide the levers firmly up or down. 2. When power is restored after installation of the wall control, push and hold the fan OFF button ( ) for 3 to 5 seconds to set the code in the receiver. 3. The sixth switch marked ON and I is for dimming control of lights: Set switch to ON to allow for dimming of the lights. Set switch to I for no dimming of the lights such as for fluorescent bulbs. Installation of Wall Control (pages 12, 13 & 14) ! WARNING Turning off wall switch is not sufficient. To avoid possible electrical shock, be sure electricity is turned off at the main fuse or circuit breaker box before wiring. All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock. 1. Remove faceplate and screws from existing wall control. Pull control out from the wall box. Determine the "hot" wire and the "load" wire and disconnect these wires from control. Do not attempt to disconnect any wires not already connected to existing control. 2. Before installing wall control, place wall control in "OFF" mode by pushing "ON/OFF" switch to the "OFF" position. 3. Connect one black wire of wall control to the "hot" wire. Securely connect wires with wire connectors supplied. 4. Connect one black wire of wall switch to the "load" (black) wire in wall box. Securely connect wires with wire connector supplied. 5. Screw wall control into wall box using the supplied screws. Leave wall control in "OFF" mode until fan installation is completed. 6. The wall control is supplied with a white, ivory, and almond color switch covers. Choose the finish that best suits your needs and snap the cover onto the wall control. 7. Install decorator wall plate using the two screws provided with wall plate. Leave wall control in "OFF" mode until fan installation is completed. ON 1 2 3 45 I BLK TO HOT 120VAC SOURCE TO LOAD BLACK OUND GR * For additional installation review full instructions on pages 13 and 14. 4 ETL Model No.: CF788

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

4
1.
Connect the green grounding lead from the hanger ball and the
green grounding lead from the hanger bracket to the grounding
conductor of supply (this may be a bare wire or wire with green
colored insulation). Securely connect wires with wire
connectors supplied.
NOTE: If you are using an Emerson Light Fixture with your fan,
see Light Fixture Owner’s Manual for wiring.
2.
Securely connect the fan motor white wire to the supply white
(neutral) wire using wire connector supplied. Securely connect
the fan motor black wire to the supply black (hot) wire using
wire connector supplied. After connections have been made,
turn leads upward and carefully push leads into
the outlet box, with the white and green leads on one side of the
outlet box and the black leads on the other side of
the outlet box.
NOTE: CEILING COVER OMITTED FOR CLARITY.
GROUND
WIRE
LISTED
WIRE
CONNECTOR (3)
GREEN WIRE
(GROUND) FROM
HANGER BRACKET
GREEN WIRE
(GROUND) FROM
HANGER BALL
WHITE SUPPLY
(NEUTRAL)
WHITE FAN
WIRE
BLACK SUPPLY
(HOT)
BLACK
FAN WIRE
Wiring Ceiling Fan
(page 11)
1.
Remove faceplate and screws from existing wall control. Pull
control out from the wall box. Determine the “hot” wire and the
“load” wire and disconnect these wires from control. Do not
attempt to disconnect any wires not already connected to
existing control.
2.
Before installing wall control, place wall control in “OFF” mode
by pushing “ON/OFF” switch to the “OFF” position.
3.
Connect one black wire of wall control to the “hot” wire.
Securely connect wires with wire connectors supplied.
4.
Connect one black wire of wall switch to the “load” (black) wire
in wall box. Securely connect wires with wire connector
supplied.
5.
Screw wall control into wall box using the supplied screws.
Leave wall control in “OFF” mode until fan installation is
completed.
6.
The wall control is supplied with a white, ivory, and almond
color switch covers. Choose the finish that best suits your
needs and snap the cover onto the wall control.
7.
Install decorator wall plate using the two screws provided with
wall plate. Leave wall control in “OFF” mode until fan installation
is completed.
ON
1
2
3
4
5
I
BLACK
BLK
HOT
T
O
1
2
0
V
A
C
S
O
U
R
C
E
T
O
L
O
A
D
G
R
O
U
N
D
Installation of Wall Control
(pages 12, 13 & 14)
1.
Separate the grounded white
neutral and green
wires on
one side of the outlet box
from the ungrounded black
and blue wires on the other
side of the outlet box
2.
Insert the grounded green
and white wires into one side
of the outlet box, and the
ungrounded black and blue
wires into the other side of
the outlet box.
3.
Screw the two threaded studs
into the tapped holes in the
hanger bracket.
Installation of Ceiling Cover
(page 11)
Your wall control has code switches which must be set in one of
32 possible code combinations. The five levers (numbered 1, 2, 3,
4, and 5) on the switches are factory-set in the ON (up) position.
Change the switch settings as follows:
1.
Slide the five switch levers in the wall control to your choice of
ON (up) or down positions. Use a ball-point pen or small
screwdriver and slide the levers firmly up or down.
2.
When power is restored after installation of the wall control,
push and hold the fan OFF button (
) for 3 to 5
seconds to set the code in the receiver.
3.
The sixth switch marked ON and I is for dimming control of
lights:
Set switch to ON to allow for dimming of the lights. Set
switch to I for no dimming of the lights such as for fluorescent
bulbs.
Programming Receiver
(page 12)
EMERSON QUICK START GUIDE
4.
Install the ceiling cover onto
the hanger bracket. using the
studs, lock washers and
knurled nuts supplied.
Turning off wall switch is not sufficient. To avoid possible electrical
shock, be sure electricity is turned off at the main fuse or circuit
breaker box before wiring. All wiring must be in accordance with
National and Local codes and the ceiling fan must be properly
grounded as a precaution against possible electrical shock.
!
WARNING
ETL Model No.: CF788
*
For additional installation review full instructions on pages