Epson DS-510 User Manual - Page 82

Environmental Specifications, USB Interface Specifications, Safety and Approvals Specifications

Page 82 highlights

Rated output voltage Rated output current DC 24 V 1.37 A Parent topic: Technical Specifications Environmental Specifications Temperature Humidity (non-condensing) Operating conditions Operating: 41 to 95 °F (5 to 35 °C) Storage: -13 to 140 °F (-25 to 60 °C) Operating: 10 to 80% RH Storage: 10 to 85% RH Ordinary office or home conditions Note: Avoid operating the scanner in direct sunlight, near a strong light source, or in extremely dusty conditions. Parent topic: Technical Specifications USB Interface Specifications Interface type Electrical standard Connector type Universal Serial Bus Specification Revision 2.0 Full Speed mode (12 Mbits per second) and Hi-Speed mode (480 Mbits per second) of Universal Serial Bus Specification Revision 2.0 One Type B port Parent topic: Technical Specifications Safety and Approvals Specifications Scanner United States Canada EMC: FCC part 15 Subpart B Class B EMC: CAN/CSA-CEI/IEC CISPR 22 Class B 82

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89

Rated output voltage
DC 24 V
Rated output current
1.37 A
Parent topic:
Technical Specifications
Environmental Specifications
Temperature
Operating: 41 to 95 °F (5 to 35 °C)
Storage: –13 to 140 °F (–25 to 60 °C)
Humidity
Operating: 10 to 80% RH
(non-condensing)
Storage: 10 to 85% RH
Operating conditions
Ordinary office or home conditions
Note:
Avoid operating the scanner in direct sunlight, near a strong light source, or in extremely dusty
conditions.
Parent topic:
Technical Specifications
USB Interface Specifications
Interface type
Universal Serial Bus Specification Revision 2.0
Electrical standard
Full Speed mode (12 Mbits per second) and Hi-Speed mode (480
Mbits per second) of Universal Serial Bus Specification Revision 2.0
Connector type
One Type B port
Parent topic:
Technical Specifications
Safety and Approvals Specifications
Scanner
United States
EMC: FCC part 15 Subpart B Class B
Canada
EMC: CAN/CSA-CEI/IEC CISPR 22 Class B
82