Fluke 117 Fluke 114,115,117 Manual - Page 10

Battery Saver (\, MIN MAX AVG Recording Mode, Display HOLD, Backlight, Manual and Autoranging

Page 10 highlights

114, 115, and 117 Users Manual Battery Saver ("Sleep Mode") The Meter automatically enters "Sleep mode" and blanks the display if there is no function change, range change, or button press for 20 minutes. Pressing any button or turning the rotary switch awakens the Meter. To disable the Sleep mode, hold down the g button while turning the Meter on. The Sleep mode is always disabled in the MIN MAX AVG mode. MIN MAX AVG Recording Mode The MIN MAX AVG recording mode captures the minimum and maximum input values (ignoring overloads), and calculates a running average of all readings. When a new high or low is detected, the Meter beeps. • Put the Meter in the desired measurement function and range. • Press p to enter MIN MAX AVG mode. • Mand MAX are displayed and the highest reading detected since entering MIN MAX AVG is displayed. • Press p to step through the low (MIN), average (AVG), and present readings. • To pause MIN MAX AVG recording without erasing stored values, press f. K is displayed. • To resume MIN MAX AVG recording, press fagain. • To exit and erase stored readings, press p for at least one second or turn the rotary switch. 8 Display HOLD XWWarning To avoid electric shock, when Display HOLD is activated, be aware that the display will not change when you apply a different voltage. In the Display HOLD mode, the Meter freezes the display. 1. Press fto activate Display HOLD. (K is displayed.) 2. To exit and return to normal operation, press f or turn the rotary switch. Backlight Press Q to toggle the backlight on and off. The backlight automatically turns off after 40 seconds. To disable backlight auto-off, hold down Q while turning the Meter on. Manual and Autoranging The Meter has both Manual and Autorange modes. • In the Autorange mode, the Meter selects the range with the best resolution. • In the Manual Range mode, you override Autorange and select the range yourself.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26

114, 115, and 117
Users Manual
8
Battery Saver ("Sleep Mode")
The Meter automatically enters "Sleep mode" and blanks
the display if there is no function change, range change, or
button press for 20 minutes. Pressing any button or
turning the rotary switch awakens the Meter. To disable the
Sleep mode, hold down the
g
button while turning the
Meter on. The Sleep mode is always disabled in the MIN
MAX AVG mode.
MIN MAX AVG Recording Mode
The MIN MAX AVG recording mode captures the minimum
and maximum input values (ignoring overloads), and
calculates a running average of all readings. When a new
high or low is detected, the Meter beeps.
Put the Meter in the desired measurement function and
range.
Press
p
to enter MIN MAX AVG mode.
M
and MAX are displayed and the highest
reading detected since entering MIN MAX AVG is
displayed.
Press
p
to step through the low (MIN), average
(AVG), and present readings.
To pause MIN MAX AVG recording without erasing
stored values, press
f
.
K
is displayed.
To resume MIN MAX AVG recording, press
f
again.
To exit and erase stored readings, press
p
for at
least one second or turn the rotary switch.
Display HOLD
XW
Warning
To avoid electric shock, when Display
HOLD is activated, be aware that the
display will not change when you
apply a different voltage.
In the Display HOLD mode, the Meter freezes the display.
1.
Press
f
to activate Display HOLD. (
K
is
displayed.)
2.
To exit and return to normal operation, press
f
or
turn the rotary switch.
Backlight
Press
Q
to toggle the backlight on and off. The backlight
automatically turns off after 40 seconds. To disable
backlight auto-off, hold down
Q
while turning the Meter
on.
Manual and Autoranging
The Meter has both Manual and Autorange modes.
In the Autorange mode, the Meter selects the range with
the best resolution.
In the Manual Range mode, you override Autorange and
select the range yourself.