Rotary Switch Positions - true rms multimeter

Page 9 highlights

True-rms Multimeters Rotary Switch Positions Rotary Switch Positions Switch Position Measurement Function Model x e Hz (button) D l Automatically selects ac or dc volts based on the sensed input with a low impedance input. AC voltage from 0.06 to 600 V. Frequency from 5 Hz to 50 kHz. DC voltage from .001 V to 600 V. AC voltage from 6.0 to 600 mV, dc-coupled. DC voltage from 0.1 to 600 mV. 114 & 117 114, 115 & 117 115 & 117 114, 115 & 117 114, 115 & 117 Ω Ohms from 0.1 Ω to 40 MΩ. s Continuity beeper turns on at < 20 Ω and turns off at >250 Ω. 114, 115 & 117 114, 115 & 117 R S j Hz (button) I w Diode Test. Displays OL above 2.0 V. Farads from 1 nF to 9999 μF. AC current from 0.1 A to 10 A (>10 to 20 A, 30 seconds on, 10 minutes off). >10.00 A display flashes. >20 A, OL is displayed. DC-coupled. Frequency from 45 Hz to 5 kHz. DC current from 0.001 A to 10 A (>10 to 20 A, 30 seconds on, 10 minutes off). >10.00 A display flashes. >20 A, OL is displayed. Non-contact sensing of ac voltage. 115 & 117 115 & 117 115 & 117 115 & 117 117 Note: All ac functions and Auto-V LoZ are true-rms. AC voltage is ac-coupled. Auto-V LoZ, AC mV and AC amps are dc-coupled. 7

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26

True-rms Multimeters
Rotary Switch Positions
7
Rotary Switch Positions
Switch
Position
Measurement Function
Model
x
Automatically selects ac or dc volts based on the sensed input with a low
impedance input.
114 & 117
e
Hz (button)
AC voltage from 0.06 to 600 V.
Frequency from 5 Hz to 50 kHz.
114, 115 & 117
115 & 117
D
DC voltage from .001 V to 600 V.
114, 115 & 117
l
AC voltage from 6.0 to 600 mV, dc-coupled. DC voltage from 0.1 to 600 mV.
114, 115 & 117
Ω
Ohms from 0.1
Ω
to 40 M
Ω
.
114, 115 & 117
s
Continuity beeper turns on at
<
20
Ω
and turns off at
>
250
Ω
.
114, 115 & 117
R
Diode Test. Displays OL above 2.0 V.
115 & 117
S
Farads from 1 nF to 9999
μ
F.
115 & 117
j
Hz (button)
AC current from 0.1 A to 10 A (>10 to 20 A, 30 seconds on, 10 minutes off).
>
10.00 A display flashes.
>
20 A,
OL
is displayed. DC-coupled.
Frequency from 45 Hz to 5 kHz.
115 & 117
I
DC current from 0.001 A to 10 A (>10 to 20 A, 30 seconds on, 10 minutes off).
>
10.00 A display flashes.
>
20 A,
OL
is displayed.
115 & 117
w
Non-contact sensing of ac voltage.
117
Note: All ac functions and Auto-V LoZ are true-rms. AC voltage is ac-coupled. Auto-V LoZ, AC mV and AC