Fluke 117 Fluke 114,115,117 Manual - Page 14
Measuring AC or DC Current (115 & 117), See Testing the Fuse - test leads
View all Fluke 117 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 14 highlights
114, 115, and 117 Users Manual Measuring AC or DC Current (115 & 117) XWWarning To avoid personal injury or damage to the Meter: • Never attempt to make an in-circuit current measurement when the opencircuit potential to earth is >600 V. • Check the Meter's fuse before testing. (See "Testing the Fuse") • Use the proper terminals, switch position, and range for your measurement. • Never place the probes in parallel with a circuit or component when the leads are plugged into the A (Amps) terminals. 1 A 2 3 edy08f.eps Turn circuit power off, break the circuit, insert the Meter in series with the circuit, and then turn circuit power on. 12
114, 115, and 117
Users Manual
12
Measuring AC or DC Current (115 & 117)
XW
Warning
To avoid personal injury or damage to the
Meter:
•
Never attempt to make an in-circuit
current measurement when the open-
circuit potential to earth is
>
600 V.
•
Check the Meter's fuse before testing.
(See “Testing the Fuse”)
•
Use the proper terminals, switch
position, and range for your measure-
ment.
•
Never place the probes in parallel with a
circuit or component when the leads are
plugged into the A (Amps) terminals.
A
1
2
3
edy08f.eps
Turn circuit power off, break the circuit, insert the Meter in
series with the circuit, and then turn circuit power on.