Fluke 1736/B Datasheet - Page 4

Specifications

Page 4 highlights

Specifications Accuracy Parameter Range Voltage 1000 V i17xx-flex 1500 12" 150 A 1500 A Current i17xx-flex 3000 24" i17xx-flex 6000 36" 300 A 3000 A 600 A 6000 A i40s-EL clamp 4 A 40 A Frequency 42.5 Hz to 69 Hz Aux input ± 10 V dc Voltage min/max 1000 V Current min/max defined by accessory THD on voltage 1000 % THD on current 1000 % Voltage harmonics 2nd ... 50th 1000 V Current harmonics 2nd ... 50th defined by accessory Unbalance 100 % Max. resolution 0.1 V 0.1 A 1 A 1 A 10 A 1 A 10 A 1 mA 10 mA 0.01 Hz 0.1 mV 0.1 V defined by accessory 0.1 % 0.1 % 0.1 V defined by accessory 0.1 % Intrinsic accuracy at reference conditions (% of reading + % of full scale) ± (0.2 % + 0.01 %) ± (1 % + 0.02 %) ± (1 % + 0.02 %) ± (1 % + 0.03 %) ± (1 % + 0.03 %) ± (1.5 % + 0.03 %) ± (1.5 % + 0.03 %) ± (0.7 % + 0.02 %) ± (0.7 % + 0.02 %) ± (0.1 %) ± (0.2 % + 0.02 %) ± (1 % + 0.1 %) ± (5 % + 0.2 %) ± 0.5 ± 0.5 ≥ 10 V: ± 5 % of reading < 10 V: ± 0.5V ≥ 3 % of current range: ± 5 % of reading < 3 % of current range: ± 0.15 % of range ± 0.2 Intrinsic uncertainty ± (% of reading + % of range)1 Parameter Influence quantity iFlex1500-12 150A/1500A iFlex3000-24 300A/3000A iFlex6000-36 600/6000A i40s-EL 4A/40A Active Power P Active Energy Ea Apparent Power S Apparent Energy Eap Reactive Power Q Reactive Energy Er Power Factor PF Displacement Power FactorDPF/cosϕ PF ≥ 0.99 0 ≤ PF ≤ 1 0 ≤ PF ≤ 1 1.2 % + 0.005 % 1.2 % + 0.005 % 1.2 % + 0.0075 % 1.2 % + 0.0075 % 1.7 % + 0.0075 % 1.7 % + 0.0075 % 1.2 % + 0.005 % 1.2 % + 0.005 % 2.5 % of measured apparent power - ± 0.025 Additional uncertainty in % of range1 VP-N > 250 V 0.015 % 0.0225 % 0.0225 % 0.015 % 1Range = 1000 V x Irange Reference conditions: • Environmental: 23 °C ± 5 °C, instrument operating for at least 30 minutes, no external electrical/magnetic field, RH 10 % of Irange • Primary conductor of clamps or Rogowski coil in center position • Temperature coefficient: Add 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C MyFlukeStore www. 4SFhluokpe CfoorproFraltuiokne pFlruokde 1u7c3t6sanodn1l7i3n8eTharte:e-Phase Power Loggers .com 1.877.766.5412

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10

Accuracy
Parameter
Range
Max. resolution
Intrinsic accuracy at reference conditions
(% of reading + % of full scale)
Voltage
1000 V
0.1 V
± (0.2 % + 0.01 %)
Current
i17xx-flex 1500 12”
150 A
1500 A
0.1 A
1 A
± (1 % + 0.02 %)
± (1 % + 0.02 %)
i17xx-flex 3000 24”
300 A
3000 A
1 A
10 A
± (1 % + 0.03 %)
± (1 % + 0.03 %)
i17xx-flex 6000 36”
600 A
6000 A
1 A
10 A
± (1.5 % + 0.03 %)
± (1.5 % + 0.03 %)
i40s-EL clamp
4 A
40 A
1 mA
10 mA
± (0.7 % + 0.02 %)
± (0.7 % + 0.02 %)
Frequency
42.5 Hz to 69 Hz
0.01 Hz
± (0.1 %)
Aux input
± 10 V dc
0.1 mV
± (0.2 % + 0.02 %)
Voltage min/max
1000 V
0.1 V
± (1 % + 0.1 %)
Current min/max
defined by
accessory
defined by
accessory
± (5 % + 0.2 %)
THD on voltage
1000 %
0.1 %
± 0.5
THD on current
1000 %
0.1 %
± 0.5
Voltage harmonics 2nd ...
50th
1000 V
0.1 V
≥ 10 V: ± 5 % of reading
< 10 V: ± 0.5V
Current harmonics 2nd ...
50th
defined by
accessory
defined by
accessory
≥ 3 % of current range: ± 5 % of reading
< 3 % of current range: ± 0.15 % of range
Unbalance
100 %
0.1 %
± 0.2
Intrinsic uncertainty ± (% of reading + % of range)
1
Parameter
Influence
quantity
iFlex1500-12
150A/1500A
iFlex3000-24
300A/3000A
iFlex6000-36
600/6000A
i40s-EL
4A/40A
Active Power P
Active Energy E
a
PF ≥ 0.99
1.2 % + 0.005 %
1.2 % +
0.0075 %
1.7 % +
0.0075 %
1.2 % + 0.005 %
Apparent Power S
Apparent Energy E
ap
0 ≤ PF ≤ 1
1.2 % + 0.005 %
1.2 % +
0.0075 %
1.7 % +
0.0075 %
1.2 % + 0.005 %
Reactive Power Q
Reactive Energy E
r
0 ≤ PF ≤ 1
2.5 % of measured apparent power
Power Factor PF
Displacement Power
FactorDPF/cos
ϕ
± 0.025
Additional uncertainty
in % of range
1
V
P-N
> 250 V
0.015 %
0.0225 %
0.0225 %
0.015 %
1
Range = 1000 V x Irange
Reference conditions:
Environmental:
23 °C ± 5 °C, instrument operating for at least 30 minutes, no external electrical/magnetic field, RH <65 %
Input conditions:
Cos
ϕ
/PF=1, Sinusoidal signal f=50 Hz/60 Hz, power supply 120 V/230 V ±10 %.
Current and power specifications:
Input voltage 1 ph: 120 V/230 V or 3 ph wye/delta: 230 V/400 V Input current: I > 10 % of Irange
Primary conductor of clamps or Rogowski coil in center position
Temperature coefficient:
Add 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C
Specifications
Shop for Fluke products online at:
1.877.766.5412