i17xx-flex 1500 12 Flexible Current Probe specifications

Page 8 highlights

i17xx-flex 1500 12" Flexible Current Probe specifications Measuring range 1 to 150 A ac/10 to 1500 A ac Nondestructive current 100 kA (50/60 Hz) Intrinsic error at reference condition* ± 0.7 % of reading Accuracy 173x + iFlex ± (1 % of reading + 0.02 % of range) Temperature coefficient over operating temperature range 0.05 % of reading/°C 0.09 % of reading/°F Working voltage 1000 V CAT III, 600 V CAT IV Probe cable length 305 mm (12 in) Probe cable diameter 7.5 mm (0.3 in) Minimum bending radius 38 mm (1.5 in) Output cable length 2 m (6.6 ft) Weight 115 g Probe cable material TPR Coupling material POM + ABS/PC Output cable TPR/PVC Operating temperature -20 °C to +70 °C (-4 °F to 158 °F) temperature of conductor under test shall not exceed 80 °C (176 °F) Temperature, non-operating -40 °C to +80 °C (-40 °F to 176 °F) Relative humidity, operating 15 % to 85 % non-condensing IP rating IEC 60529:IP50 Warranty One-year * Reference condition: • Environmental: 23 °C ± 5 °C, no external electrical/magnetic field, RH 65 % • Primary conductor in center position MyFlukeStore www. 8SFhluokpe CfoorproFraltuiokne pFlruokde 1u7c3t6sanodn1l7i3n8eTharte:e-Phase Power Loggers .com 1.877.766.5412

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10

i17xx-flex 1500 12” Flexible Current Probe specifications
Measuring range
1 to 150 A ac/10 to 1500 A ac
Nondestructive current
100 kA (50/60 Hz)
Intrinsic error at reference condition*
± 0.7 % of reading
Accuracy 173x + iFlex
± (1 % of reading + 0.02 % of range)
Temperature coefficient over operating temperature range
0.05 % of reading/°C 0.09 % of reading/°F
Working voltage
1000 V CAT III, 600 V CAT IV
Probe cable length
305 mm (12 in)
Probe cable diameter
7.5 mm (0.3 in)
Minimum bending radius
38 mm (1.5 in)
Output cable length
2 m (6.6 ft)
Weight
115 g
Probe cable material
TPR
Coupling material
POM + ABS/PC
Output cable
TPR/PVC
Operating temperature
-20 °C to +70 °C (-4 °F to 158 °F) temperature of
conductor under test shall not exceed 80 °C (176 °F)
Temperature, non-operating
-40 °C to +80 °C (-40 °F to 176 °F)
Relative humidity, operating
15 % to 85 % non-condensing
IP rating
IEC 60529:IP50
Warranty
One-year
* Reference condition:
• Environmental: 23 °C ± 5 °C, no external electrical/magnetic field, RH 65%