Power Recorder Symbols Symbols Symbols used in this manual and on the Recorder are listed in Table 1. Table 1. Symbols X Hazardous voltage. Risk of electrical shock. Conforms to requirements of European P Union and European Free Trade Association (EFTA). ) Canadian Standards Association. [ Note: Canadian and US. ] CAT III CAT III equipment is designed to protect against transients in equipment in fixedequipment installations, such as distribution panels, feeders and short branch circuits, and lighting systems in large buildings. W Risk of danger. Important information. See manual. Do not dispose of this product as unsorted ~ municipal waste. Go to Fluke's web site for recycling information. . Protective conductor terminal. CAT IV CAT IV equipment is designed to protect against transients from the primary supply level, such as an electricity meter or an overhead or underground utility service. Specifications for the System: Recorder and Power Analyze Software General Specifications Power Quality Measurement Standards Conformance IEC 61999-1-4 Class 1, IEC 61000-4-30 Class A or B depending on measurement function, IEEE519, IEEE1159, IEEE1459 Clock/Calendar Leap years, 24-hour clock Real-time Clock Accuracy Not more than ± 1 s/day Internal Memory Capacity for Data At least 1 GB Maximum Recording Period At least 31 days Measurement Time Control Automatic Maximum Number of Events Limited only by the size of the internal memory. Power Requirements 100 to 240 V rms ± 10 %, 47-63 Hz, 40 W Operating Time During Interruptions (internal UPS operation 5 minutes per interruption, 60 minutes total operating time without recharging Dimensions 215 x 310 x 35 mm (8.5 x 12.2 x 3.5 inch) Mass (Weight 6.3 kg (14 lbs) Input Specifications Measurement Types One Phase Plus Neutral, One Phase IT No Neutral, One Phase Split Phase, Three Phase Wye, Three Phase Delta, Three Phase IT, Three Phase High Leg, Three Phase Open Leg, 2 Element Delta, 2 ½ Element Wye Input Channels Voltage: 5 channels, AC/DC Current: 5 channels Voltage Channels Input resistance: 2 MΩ Input capacitance:

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

Power Recorder
Symbols
3
Symbols
Symbols used in this manual and on the Recorder are listed in Table 1.
Table 1. Symbols
X
Hazardous voltage. Risk of electrical
shock.
W
Risk of danger. Important information. See
manual.
P
Conforms to requirements of European
Union and European Free Trade
Association (EFTA).
~
Do not dispose of this product as unsorted
municipal waste. Go to Fluke’s web site for
recycling information.
)
Canadian Standards Association
.
[
Note
: Canadian and US. ]
.
Protective conductor terminal.
CAT III
CAT III
equipment is designed to protect
against transients in equipment in fixed-
equipment installations, such as
distribution panels, feeders and short
branch circuits, and lighting systems in
large buildings.
CAT IV
CAT IV
equipment is designed to protect
against transients from the primary supply
level, such as an electricity meter or an
overhead or underground utility service.
Specifications for the System: Recorder and Power Analyze
Software
General Specifications
Power Quality Measurement Standards
Conformance
.....................................................
IEC 61999-1-4 Class 1, IEC 61000-4-30 Class A or B depending on
measurement function, IEEE519, IEEE1159, IEEE1459
Clock/Calendar
..................................................
Leap years, 24-hour clock
Real-time Clock Accuracy
................................
Not more than
±
1 s/day
Internal Memory Capacity for Data
.................
At least 1 GB
Maximum Recording Period
............................
At least 31 days
Measurement Time Control
.............................
Automatic
Maximum Number of Events
...........................
Limited only by the size of the internal memory.
Power Requirements
........................................
100 to 240 V rms
±
10 %, 47-63 Hz, 40 W
Operating Time During Interruptions
(internal UPS operation)
.....................................
5 minutes per interruption, 60 minutes total operating time without
recharging
Dimensions
.......................................................
215 x 310 x 35 mm (8.5 x 12.2 x 3.5 inch)
Mass (Weight)
...................................................
6.3 kg (14 lbs)
Input Specifications
Measurement Types
.........................................
One Phase Plus Neutral, One Phase IT No Neutral, One Phase Split
Phase, Three Phase Wye, Three Phase Delta, Three Phase IT, Three
Phase High Leg, Three Phase Open Leg, 2 Element Delta, 2 ½
Element Wye
Input Channels
..................................................
Voltage: 5 channels, AC/DC
Current: 5 channels
Voltage Channels
..............................................
Input resistance: 2 M
Input capacitance: <20 pF
Current Channels
..............................................
1 M
Ω
. Self-identifying probes
Types available: current clamps, Flexi-CTs
Measuring Method
............................................
Simultaneous digital sampling of voltage and current. Digital PLL
synchronized sampling, internal frequency reference used during
voltage drops.