Fluke 1750 Fluke 1750 Operators Manual - Page 60

External Interface Specifications, Inter-harmonic Voltage and Current Intermediate Harmonics - power factor

Page 60 highlights

1750 Operators Manual Power Factor Measurement Range 1.000 (leading) to 0.000 to +1.000 (lagging) Measurement Accuracy 1 digit from the calculation of each measured value (± 3 digits for total) Displacement Power Factor Measurement Method Calculated from the phase difference between voltage fundamental and current fundamental Measurement Range 1.000 (leading) to 0.000 to + 1.000 (lagging) Measurement Accuracy 0.5 % reading ± 2 % full scale ± 1 digit Voltage Unbalance and Phase Sequence Measurement Method Positive sequence voltage divided by negative sequence voltage, per IEC 61000-4-30 Harmonic Voltage and Current Analysis Window rectangular Analysis Order 1st to 50th order Measurement Accuracy Voltage / Current: 1st to 20th orders: ± 0.5 % reading ± 0.2 % full scale 21st to 50th orders: ± 1 % reading ± 0.3 % full scale (current sensor accuracy must be included for current and power) Measurement Method IEC 61000-4-7:2002 Inter-harmonic Voltage and Current (Intermediate Harmonics) Analysis Window rectangular Analysis Orders 0.5 to 49.5th order Measurement Method IEC 61000-4-7:2002 Voltage flicker Measurement Method as per IEC 61000-4-15:2003: 10 min (Pst), 2 h (Plt) External Interface Specifications LAN Interface Connector RJ-45 Speed and Type 10/100 Base-T, auto MDIX Communications Protocol TCP/IP over Ethernet Wireless Controller Interface Connection wireless (2.4 GHz radio) Speed up to 700 kbit/second Communications Protocol Bluetooth SPP Environmental and Safety Specifications Operating Environment indoors or in covered area outdoors, up to 2000 m altitude Storage Temperature and Humidity 20 °C to 50 °C, 80 % rh max, non-condensing Operating Temperature and Humidity 0 °C to 40 °C, 80 % rh max, non-condensing Maximum Rated Working Voltage Voltage Terminals 1100 V rms Voltage Durability 5550 V rms ac for 1 minute, between voltage input terminals, voltage input terminals and current probes, and voltage input terminals and case (50/60 Hz, 1 mA sense current) Enclosure Protection IP30 (per EN 60529) Standards Conformance EMC IEC 61326-1:2006 Class A IEC 61000-3-2:2005, 3rd Edition IEC 61000-3-3:2005, 1.2 Edition AS/NZS 4268:2008 (BT module only) ETSI EN300328 (V1.7.1:2006) Safety IEC 61010-1:2001, 2nd Edition Voltage input unit: Contamination Level 2 Overvoltage Category 1000 V CAT III, 600 V CAT IV (anticipated overvoltage: 8000 V) 52

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60

1750
Operators Manual
52
Power Factor
Measurement Range
..........................................
-1.000 (leading) to 0.000 to +1.000 (lagging)
Measurement Accuracy
......................................
±
1 digit from the calculation of each measured value (
±
3 digits for
total)
Displacement Power Factor
Measurement Method
.........................................
Calculated from the phase difference between voltage fundamental
and current fundamental
Measurement Range
..........................................
-1.000 (leading) to 0.000 to + 1.000 (lagging)
Measurement Accuracy
......................................
± 0.5 % reading ± 2 % full scale ± 1 digit
Voltage Unbalance and Phase Sequence
Measurement Method
.........................................
Positive sequence voltage divided by negative sequence voltage, per
IEC 61000-4-30
Harmonic Voltage and Current
Analysis Window
.................................................
rectangular
Analysis Order
....................................................
1st to 50th order
Measurement Accuracy
......................................
Voltage / Current: 1st to 20th orders: ± 0.5 % reading ± 0.2 % full scale
21st to 50th orders: ± 1 % reading ± 0.3 % full scale (current sensor
accuracy must be included for current and power)
Measurement Method
.........................................
IEC 61000-4-7:2002
Inter-harmonic Voltage and Current (Intermediate Harmonics)
Analysis Window
.................................................
rectangular
Analysis Orders
..................................................
0.5 to 49.5th order
Measurement Method
.........................................
IEC 61000-4-7:2002
Voltage flicker
Measurement Method
.........................................
as per IEC 61000-4-15:2003: 10 min (Pst), 2 h (Plt)
External Interface Specifications
LAN Interface
Connector
...........................................................
RJ-45
Speed and Type
.................................................
10/100 Base-T, auto MDIX
Communications Protocol
...................................
TCP/IP over Ethernet
Wireless Controller Interface
Connection
..........................................................
wireless (2.4 GHz radio)
Speed
..................................................................
up to 700 kbit/second
Communications Protocol
...................................
Bluetooth SPP
Environmental and Safety Specifications
Operating Environment
.......................................
indoors or in covered area outdoors, up to 2000 m altitude
Storage Temperature and Humidity
....................
-20
°
C to 50
°
C, 80 % rh max, non-condensing
Operating Temperature and Humidity
................
0
°
C to 40
°
C, 80 % rh max, non-condensing
Maximum Rated Working Voltage
Voltage Terminals
...............................................
1100 V rms
Voltage Durability
................................................
5550 V rms ac for 1 minute, between voltage input terminals, voltage
input terminals and current probes, and voltage input terminals and
case (50/60 Hz, 1 mA sense current)
Enclosure Protection
...........................................
IP30 (per EN 60529)
Standards Conformance
EMC
....................................................................
IEC 61326-1:2006 Class A
IEC 61000-3-2:2005, 3
rd
Edition
IEC 61000-3-3:2005, 1.2 Edition
AS/NZS 4268:2008 (BT module only)
ETSI EN300328 (V1.7.1:2006)
Safety
..................................................................
IEC 61010-1:2001, 2
nd
Edition
Voltage input unit: Contamination Level 2
Overvoltage Category 1000 V CAT III, 600 V CAT IV (anticipated
overvoltage: 8000 V)