Fluke 196C FE 192,196,199 C Users Manual - Page 109
Power, Phase, Temperature TEMP, Decibel dB, Automatic Scope Measurements
View all Fluke 196C manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 109 highlights
Power Power Factor ratio between Watts and VA Range 0.00 to 1.00 Watt RMS reading of multiplication corresponding samples of input A (volts) and Input B (amperes) Full Scale Reading 999 counts VA Vrms x Arms Full Scale Reading 999 counts VA Reactive VA)2-W2) Full Scale Reading 999 counts Phase Range 180 to +180 degrees Resolution 1 degree Accuracy 0.1 Hz to 1 MHz 2 degrees 1 MHz to 10 MHz 3 degrees 9 Specifications Automatic Scope Measurements Temperature (TEMP) With Optional Temperature Probe Ranges (°C or °F 40.0 to +100.0 ° -100 to +250 ° -100 to +500 ° -100 to +1000 ° -100 to + 2500 ° Probe Sensitivity 1 mV/°C and 1 mV/°F Decibel (dB) dBV dB relative to one volt dBm dB relative to one mW in 50 Ω or 600 Ω dB on VDC, VAC, or VAC+DC Accuracy same as VDC, VAC, VAC+DC 101