Fluke Ti450 User Manual - Page 67

Detailed Specifications

Page 67 highlights

Thermal Imagers Detailed Specifications Detailed Specifications Temperature Measurements Temperature Range (not calibrated below -10 °C) Ti200, Ti300 20 °C to +650 °C Ti400, Ti450 20 °C to +1200 °C Accuracy 2 °C or 2 % (whichever is greater) at 25 °C ambient On-screen emissivity correction all models On-screen reflected background temperature compensation all models On-screen transmission correction all models Imaging Performance Image Capture Frequency 9 Hz or 60 Hz refresh rate depending on model variation Detector Type: Focal Plane Array, uncooled microbolometer Ti400, Ti450 320 X 240 Ti300 240 X 180 Ti200 200 X 150 SuperResolution Ti450 Captures and combines 4X the data to create a 640 x 480 image Thermal Sensitivity (NETD) Ti450 0.05 °C at 30 °C target temp (50 mK) (30 mK in Filter Mode) Ti300, Ti400 0.05 °C at 30 °C target temp (50 mK) Ti200 0.075 °C at 30 °C target temp (75 mK) Total pixels Ti400, Ti450 76 800 Ti300 43 200 Ti200 30 000 Infrared spectral band 7.5 μm to 14 μm (long wave) Visual (Visible Light) Camera Type Industrial performance 5.0 MP Parallax alignment with standard IR lens From ~60 cm (~24 in) to infinity 63

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70

Thermal Imagers
Detailed Specifications
63
Detailed Specifications
Temperature Measurements
Temperature Range (not calibrated below -10
°
C)
Ti200, Ti300
....................................................
-20 °C to +650 °C
Ti400, Ti450
....................................................
-20 °C to +1200 °C
Accuracy
.............................................................
±
2
°
C or 2 % (whichever is greater) at
25
°
C ambient
On-screen emissivity correction
..........................
all models
On-screen reflected background
temperature compensation
.................................
all models
On-screen transmission correction
.....................
all models
Imaging Performance
Image Capture Frequency
..................................
9 Hz or 60 Hz refresh rate depending
on model variation
Detector Type: Focal Plane Array, uncooled microbolometer
Ti400, Ti450
....................................................
320 X 240
Ti300
...............................................................
240 X 180
Ti200
...............................................................
200 X 150
SuperResolution
Ti450
...............................................................
Captures and combines 4X the data to
create a 640 x 480 image
Thermal Sensitivity (NETD)
Ti450
...............................................................
0.05 °C at 30 °C target temp (50 mK)
(30 mK in Filter Mode)
Ti300, Ti400
....................................................
0.05 °C at 30 °C target temp (50 mK)
Ti200
...............................................................
0.075 °C at 30 °C target temp (75 mK)
Total pixels
Ti400, Ti450
....................................................
76 800
Ti300
...............................................................
43 200
Ti200
...............................................................
30 000
Infrared spectral band
.........................................
7.5
μ
m to 14
μ
m (long wave)
Visual (Visible Light) Camera
Type
....................................................................
Industrial performance 5.0 MP
Parallax alignment with
standard IR lens
.................................................
From ~60 cm (~24 in) to infinity