Frigidaire FF03DISPC1 Complete Owners Guide - Page 8

Connection, Grounding Instructions

Page 8 highlights

8 CONNECTION (CONTINUED) & GROUNDING INSTRUCTIONS B. Connect dishwasher hose (see 5C) using hose clamp. Make sure all plumbing connections are tight and in accordance with all plumbing codes and ordinances. Run water and check for leaks. Grounding Instructions FOR WASTE DISPOSERS EQUIPPED WITH A GROUNDED PLUG-IN POWER CORD. B. This appliance must be grounded. In the event of a malfunction or breakdown, grounding provides a path of least resistance for electric current to reduce the risk of electric shock. This appliance is equipped with a cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances. If the supply cord is damaged it must be replaced by the manufacturer, its service agent or similarly qualified person in order to avoid a hazard. 6. ELECTRICAL CONNECTIONS A. Connect disposer to appropriate household current only. WARNING IMPROPER CONNECTION OF THE EQUIPMENTGROUNDING CONDUCTOR CAN RESULT IN A RISK OF ELECTRIC SHOCK. CHECK WITH A QUALIFIED ELECTRICIAN OR SERVICEMAN IF YOU ARE IN DOUBT AS TO WHETHER THE APPLIANCE IS PROPERLY GROUNDED. DO NOT MODIFY THE PLUG PROVIDED WITH THE APPLIANCE IF IT WILL NOT FIT THE OUTLET. HAVE A PROPER OUTLET INSTALLED BY A QUALIFIED ELECTRICIAN. The receptacle to which this appliance is connected must be controlled by a switch. PERMANENT WIRE INSTALLATION INSTRUCTIONS For waste disposers NOT equipped with a grounded plug-in power cord. GROUNDING: This disposer must be connected to a grounded, metal, permanent wiring system; or an equipmentgrounding conductor must be run with the circuit conductors and connected to the equipment-grounding terminal or lead on the disposer. An acceptable motor control switch with a marked off position shall be provided at the time of installation to disconnect the disposer from all ungrounded supply conductors. The switch shall be mounted in sight of the disposer or in sight of the sink opening for the disposer. WARNING Electric Shock Turn off power before installing or servicing disposer. All wiring must comply with local electrical codes. Do not connect electrical current at main breaker panel until adequate ground is established. Inadequate connection of the ground wire can result in a risk of electric shock. Consult with a certified electrician or tradesman if there is any doubt whether the disposer in inadequately grounded. Your disposer must be adequately grounded.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15

8
B. Connect dishwasher hose (see 5C) using hose clamp.
Make sure all plumbing connections are tight and in
accordance with all plumbing codes and ordinances. Run
water and check for leaks.
CONNECTION
(CONTINUED) &
GROUNDING INSTRUCTIONS
6. ELECTRICAL CONNECTIONS
A. Connect disposer to appropriate household current only.
WARNING
IMPROPER CONNECTION OF THE EQUIPMENT-
GROUNDING CONDUCTOR CAN RESULT IN A RISK
OF ELECTRIC SHOCK. CHECK WITH A QUALIFIED
ELECTRICIAN OR SERVICEMAN IF YOU ARE IN
DOUBT AS TO WHETHER THE APPLIANCE IS
PROPERLY GROUNDED. DO NOT MODIFY THE
PLUG PROVIDED WITH THE APPLIANCE IF IT WILL
NOT FIT THE OUTLET. HAVE A PROPER OUTLET
INSTALLED BY A QUALIFIED ELECTRICIAN.
The receptacle to which this appliance is
connected must be controlled by a switch.
Grounding Instructions
FOR WASTE DISPOSERS EQUIPPED WITH A
GROUNDED PLUG-IN POWER CORD.
B.
This appliance must be grounded. In the event of a
malfunction or breakdown, grounding provides a path
of least resistance for electric current to reduce the
risk of electric shock. This appliance is equipped with
a cord having an equipment-grounding conductor and
a grounding plug. The plug must be plugged into an
appropriate outlet that is properly installed and grounded
in accordance with all local codes and ordinances. If
the supply cord is damaged it must be replaced by the
manufacturer, its service agent or similarly qualified person
in order to avoid a hazard.
PERMANENT WIRE INSTALLATION
INSTRUCTIONS
For waste disposers NOT equipped with a
grounded plug-in power cord.
GROUNDING:
This disposer must be connected to a
grounded, metal, permanent wiring system; or an equipment-
grounding conductor must be run with the circuit conductors
and connected to the equipment-grounding terminal or lead on
the disposer.
An acceptable motor control switch with a marked off
position
shall be provided at the time of installation to disconnect the
disposer from all ungrounded supply conductors. The switch
shall be mounted in sight of the disposer or in sight of the sink
opening for the disposer.
WARNING
Electric Shock
Turn off
power before installing or servicing disposer. All
wiring must comply with local electrical codes.
Do not connect electrical current at main breaker panel until
adequate ground is established. Inadequate connection of
the ground wire can result in a risk of electric shock. Consult
with a certified electrician or tradesman if there is any doubt
whether the disposer in inadequately grounded.
Your