Frigidaire FFEH3054US Installation Instructions - Page 2
Clearances and Dimensions - range
View all Frigidaire FFEH3054US manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 2 highlights
30" ELECTRIC FRONT CONTROL FREESTANDING INSTALLATION INSTRUCTIONS 1. Clearances and Dimensions a. Provide adequate clearances between the range and adjacent combustible surfaces. b. Location-Check location where the range will be installed. Check for proper electrical supply and the stability of floor. c. Dimensions that are shown must be used. Given dimensions provide minimum clearance. Contact surface must be solid and level. Front Typical cabinet installation view Side view Minimum to 1" wall on either side of range above 36" height. 30" Minimum 30" Minimum* Minimum to 18" cabinets on either side of range 13" Maximum depth for cabinets above range top. 25" Max. 29 7/8" 36 5/8" ± 1/4" Maximum 36" FRONT VIEW SIDE VIEW 30" Fig. 1 Minimum 0" clearance below cooking top and at rear of range 30" (762 mm) 30" (762 mm) Minimum Minimum to wall on either side of 1" range above (25 mm) 36'' (914 mm) height. *30" (762 mm) MINIMUM Minimum to 18" cabinets on 13" 330 mm (457 mm) either side of Maximum depth range. for cabinets CLEARANCE BETWabEovEe rNangeTtHop.E TOP OF THE COOKING SURFACE AND THE BOTT2O5" M OF AN UNPROTECTED WOOD OR METAL CABINE6T3;5OmmR 36" 24" (610 mm) MINIMUM WHEN BOTTOM OF WOOD OR (914 mmM) ETAL CABINET IS PROTECTED BY NOT LESS THAN 1/4" (6 mm) FLAME RETARDANT MILLBOARD COVERED WITH NOT LESS THAN NO. 28 MSG SHEET STEEL, 0.015" (0.4 mm) STAINLESS STEEL, 0.024" (0.6 mm) ALUMINUM OR 0.020" (0.5 m(m7632)0m"CmO) PPE0"R(0.m0m") c(le0aramncembe)loCw cLoEokAingRtoAp aNndCatEreaIrSof range. ROAVNEGRTAAEHLLLLE MINIMUM FOR THE REAR OF TH2E5- 3R/4A" NGE. FOLLOW DIMENSION REQUI(7R632E0m"Mm)ENTS(6P54RmOm)VIDED ABOVE DIMENTSOIOPNRS EVENT PROPERTY DAMAGE, POTENTIAL FIRE HAZARD,AND INCORRECT COUNTERTOPAND CABINET CUTS. Centerline of range Fig. 2 26 6/8" Door 47" open BACK VIEW All dimensions for electrical outlet location are maximum. Dashed cubed area shows where the electrical outlet must be installed for flush to the wall installation. 11" (279 mm) 22" (559 mm) TO ELIMINAT4E8" THE RISK OF BURNS OR FIRE BY REACHING (OM12aV1x9imEmuRmm) HEATED STORAGE SPACE LOCATED SURFACE UNIT36S,1/C8"ABINET ABOVE THE S(9U14RmmF)A(3CmEm)UNITS SHOULD BE AVOIDED. IF CABINET STORAGE IS TO BE PROVIDED, THE RISK CAN BE REDUCED BY INSTALLING A RANGE HOOD49T" HAT PROJECTS HORIZONTALLY A MINIMUM OF 5(1"24(51m2m7) Maximum mm) BEY2O9- N7/8D" THE BOTTOM OF THE CABINETSD.oor Open (759 mm) 6" (152 mm) 2-5/8" (67 mm) for models equipped with warmer drawers 3-1/2" (89 mm) for models equipped with storage drawers Wall Edge Fig. 3 2