Frigidaire FHWC3655LS Complete Owner's Guide (English) - Page 5

Installing the hood - range hood

Page 5 highlights

Installing the hood 5 IMPORTANT 3 Save installation instructions for electrical inspector's use. The range hood must be connected with copper wire only. The range hood should be connected directly 4 to the fused disconnect (or circuit breaker) box through metal electrical conduit. Wire sizes must conform to the requirements of 5 the National Electrical Code ANSI/NFPA 70 - latest edition", or CSA Standards C22.1-94, Canadian Electrical Code Part 1 and C22.2 No.0-M91 - latest edition** and all local codes and ordinances. 6 A U.L.- or C.S.A.-listed conduit connector must be provided at each end of the power supply conduit (at the range hood and at the junction box). 7 Copies of the standards listed may be obtained from: * National Fire Protection Association Batterymarch 8 Park Quincy, Massachusetts 02269 ** CSA International 8501 East Pleasant Valley Road Cleveland, Ohio 44131-5575 9 Power requirement: 120V~, 60Hz, 15 or 20A branch circuit 10 Intended use 11 • Your range hood is intended for exhaust operation only. This range hood is not recommended to be 12 used over indoor grills. Do not use it to exhaust hazardous or explosive materials or vapors. 13 Parts supplied No. Part Qty. 14 1 Range hood 1 15 Upper bracket 1 Lower bracket 1 Plantilla (estarcido) Collar 1 Recirculation kit (optional accessories) 1 FHWRKT55LS Bulb 20W, 120V~, GU10 (pre- 2 assembled) Long screw (4mm x 32mm) 8 Wall plug 8 Short screw (4mm x 12mm) 4 Wood screw (4mm x 50mm) 4 Stainless steel screw 2 (3.5mm x 10mm) Short screw (3.5mmx8mm) 2 10' extension chimney kit (optional 1 accessories) -FW10EX55LS Assembly template (stencilled) 1 2 Upper and lower chimney 1 + 1 GB

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13

5
GB
IMPORTANT
Save
installation
instructions
for
electrical
inspector’s use.
The range hood must be connected with copper
wire only.
The range hood should be connected directly
to the fused disconnect (or circuit breaker) box
through metal electrical conduit.
Wire sizes must conform to the requirements of
the National Electrical Code ANSI/NFPA 70 – latest
edition”, or CSA Standards C22.1-94, Canadian
Electrical Code Part 1 and C22.2 No.0-M91 – latest
edition** and all local codes and ordinances.
A U.L.- or C.S.A.-listed conduit connector must be
provided at each end of the power supply conduit (at
the range hood and at the junction box).
Copies of the standards listed may be obtained
from:
* National Fire Protection Association Batterymarch
Park Quincy, Massachusetts 02269
** CSA International 8501 East Pleasant Valley Road
Cleveland, Ohio 44131-5575
Power requirement:
120V~, 60Hz, 15 or 20A branch circuit
Intended use
Your range hood is intended for exhaust operation
only. This range hood is not recommended to be
used over indoor grills. Do not use it to exhaust
hazardous or explosive materials or vapors.
Parts supplied
No.
Part
Qty.
1
Range hood
1
2
Upper and lower
chimney
1
+
1
3
Upper bracket
1
4
Lower bracket
1
5
Collar
1
6
Recirculation kit
(optional
accessories)
FHWRKT55LS
1
7
Bulb
20W, 120V~,
GU10 (pre-
assembled)
2
8
Long screw
(4mm x 32mm)
8
9
Wall plug
8
10
Short screw
(4mm x 12mm)
4
11
Wood screw
(4mm x 50mm)
4
12
Stainless steel
screw
(3.5mm x 10mm)
2
13
Short screw
(3.5mmx8mm)
2
14
10’ extension
chimney kit
(optional
accessories)
-FW10EX55LS
1
15
Plantilla
(estarcido)
Assembly template
(stencilled)
1
Installing the hood