Frigidaire FHWC3655LS Complete Owner's Guide (English) - Page 9

Danger, Important

Page 9 highlights

Installing the hood 9 Electrical connections DANGER Danger of electric shock! All fittings must be installed by a competent person in accordance with current wiring regulations and local building regulations. If in doubt, consult a qualified electrician. • Mount the junction box onto the range hood using 2 short screws (13) (fig. ). fig. IMPORTANT Always switch off the electricity supply at the mains during installation, cleaning and maintenance. We recommend that the fuse is withdrawn or circuit breaker switched off at the distribution board while work is in progress. Step 4: • Loosen the 2 short screws from the junction box (fig. ). ffigig.. Step 5: • Insert the upper chimney (2) into the lower chimney (3) from top to bottom (fig. ). • Mount lower chimney (2) on the range hood (1). • Fit the tab, which is bend by 90 degrees, into the lower bracket notch and mount to the lower bracket (4) (fig. / ). • Fix it with 2 screws (12) (fig. ). fig. fig. fig. • Connect the incoming positive, neutral and ground cables to the respective terminals. The ground cable is already pre-assembled onto the junction box to provide grounding (fig. ). fig. L (live) = Black N (neutral) = White (ground) = Green L N • Pull the upper chimney (2) to the upward position to match the screw hole of the upper bracket. Mount to the upper bracket (3) with 2 side screws (10) (fig. ). GB

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13

9
GB
Electrical connections
DANGER
Danger of electric shock! All fittings must be
installed by a competent person in accordance
with current wiring regulations and local
building regulations. If in doubt, consult a
qualified electrician.
IMPORTANT
Always switch off the electricity supply at
the mains during installation, cleaning and
maintenance. We recommend that the fuse is
withdrawn or circuit breaker switched off at the
distribution board while work is in progress.
Step 4:
Loosen the 2 short screws from the junction box
(fig.
)
.
fig.
fig.
Connect
the
incoming
positive,
neutral
and
ground cables to the respective terminals. The
ground cable is already pre-assembled onto the
junction box to provide grounding (fig.
).
fig.
fig.
L (live) = Black
(ground) = Green
N (neutral) = White
L
N
Mount the junction box onto the range hood
using 2 short screws (13) (fig.
).
fig.
Step 5:
Insert the upper chimney (2) into the lower chimney
(3) from top to bottom (fig.
).
Mount lower chimney (2) on the range hood (1).
Fit the tab, which is bend by 90 degrees, into the
lower bracket notch and mount to the lower bracket
(4) (fig.
/
).
Fix it with 2 screws (12) (fig.
).
fig.
fig.
fig.
fig.
fig.
fig.
Pull the upper chimney (2) to the upward position
to match the screw hole of the upper bracket.
Mount to the upper bracket (3) with 2 side screws
(10) (fig.
).
Installing the hood