• Flexible metal round ducts should only be used when no other duct fitting exists. Limit use to short lengths and do not crush when making corners. Examples of possible ducting or air recirculation fig. Roof pitch with flashing and cap Sidewall cap Recirculator Installing the hood 7 fig. Pipe Collar Pipe Collar Pipe Collar IMPORTANT Framing must be capable of supporting 100 lbs. Installing range hood to the wall (Exhaust operation) IMPORTANT This range hood is very heavy. Adequate structure and support must be provided in all types of installations. Install framing for hood support • If drywall is present, mark the screw hole locations. • Cut away enough drywall to expose 2 vertical studs at the holes location indicated by the template. Install two horizontal supports at least 1" x 6" between two wall studs at the bottom and top mounting holes installation location (fig. ). • The horizontal support must be flush with the room side of the studs. Use cleats behind both sides of the support to secure to wall studs. • Reinstall drywall and refinish. Step 1: • Make sure that no cables or pipes will become damaged (e.g. electric, gas, water; test the areas in question with a cable detector). • Using supplied template (17), mark and drill 8 holes in the wall. Drill the holes according to the measured distances from the diagram (fig. ). • Upper/Lower bracket (4, 5): Insert 4 wall plugs (11) into the 4 drilled holes. • Range hood (1): Installation is depending on wall type: Wall type Required fasteners Wood No wall plugs (11) required Brick/Concrete 4 wall plugs (11) GB

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13

7
GB
Flexible metal round ducts should only be used
when no other duct fitting exists. Limit use to
short lengths and do not crush when making
corners.
Examples of possible ducting or air
recirculation
Sidewall cap
Recirculator
Roof pitch with
flashing and cap
Pipe
Collar
Pipe
Pipe
Collar
Collar
fig.
Installing range hood to the wall
(Exhaust operation)
IMPORTANT
This range hood is very heavy. Adequate structure
and support must be provided in all types of
installations.
Install framing for hood support
If
drywall
is
present,
mark
the
screw
hole
locations.
Cut away enough drywall to expose 2 vertical
studs at the holes location indicated by the
template. Install two horizontal supports at least
1” x 6” between two wall studs at the bottom and
top mounting holes installation location (fig.
).
The horizontal support must be flush with the
room side of the studs. Use cleats behind both
sides of the support to secure to wall studs.
Reinstall drywall and refinish.
fig.
IMPORTANT
Framing must be capable of supporting 100 lbs.
Step 1:
Make sure that no cables or pipes will become
damaged (e.g. electric, gas, water; test the areas
in question with a cable detector).
Using supplied template (17), mark and drill 8
holes in the wall. Drill the holes according to the
measured distances from the diagram (fig.
).
Upper/Lower bracket (4, 5): Insert 4 wall plugs
(11) into the 4 drilled holes.
Range hood (1): Installation is depending on wall
type:
Wall type
Required fasteners
Wood
No wall plugs (11)
required
Brick/Concrete
4 wall plugs (11)
Installing the hood