Frigidaire FPGH3077RF Installation Instructions - Page 2

Gas Range Installation Instructions - manual

Page 2 highlights

30" GAS RANGE INSTALLATION INSTRUCTIONS Clearances and Dimensions 1. Location-Check location where the range will be installed. Check for proper electrical and gas supply, and the stability of floor. 2. Dimensions that are shown must be used. Given dimensions provide minimum clearance. Contact surface must be solid and level. Front View 29 7/8" Front Typical cabinet installation view Side view 36 3/8" ± 1/4" Maximum Minimum to 8" wall on either side of range above 36" height. 30" 36" Minimum* Minimum to 18" cabinets on either side of range 13" Maximum depth for cabinets above range top. 25" Max. 36" 26" Door 46" open * 33" minimum clearance between the top of the cooking surface and the bottom of an unprotected wood or metal cabinet; or 24" minimum when bottom of wood or metal cabinet is protected by not less than ¼" flame retardant millboard covered with not less than no. 28 MSG sheet steel, 0.015" stainless steel, 0.024" aluminum or 0.020" copper. The minimum clearance is 0" for the rear of the range. Follow all dimension requirements provided above to prevent property damage, potential fire hazard, and incorrect countertop and cabinet cuts. DO NOT MAKE ANY ATTEMPT TO OPERATE THE ELECTRIC IGNITION OVEN DURING AN ELECTRICAL POWER FAILURE. RESET ALL OVEN CONTROLS TO OFF IN THE EVENT OF A POWER FAILURE. The electric ignitor will automatically re-ignite the oven burner when power resumes if the oven thermostat control was left in the ON position. When an electrical power failure occurs during use, the surface burners will continue to operate. During a power outage, the surface burners can be lit with a match. Hold a lighted match to the burner, then slowly turn the knob to the Lite position. Use extreme caution when lighting burners this way. 30 1/8" 0" clearance below cooking top and at rear of range Avoid locating cabinet storage space above the surface burners. Avoid locating cabinet storage space above the surface burners. The absence of cabinets will eliminate the chance of cabinets catching on fire, and eliminate the possibility of receiving personal burns from reaching for the cabinets over flaming surface burners. If cabinet storage is to be provided, risk can be reduced by installing a range hood that projects horizontally a minimum of 5" beyond the bottom of the cabinets. Special instructions for appliances installed in the state of Massachusetts: This Appliance can only be installed in the state of Massachusetts by a Massachusetts licensed plumber or gas fitter. When using a flexible connector, it must not exceed three (3) feet (36 in.) long. A "T" handle type manual gas valve must be installed in the gas supply line to this appliance. 2

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

2
30" GAS RANGE INSTALLATION INSTRUCTIONS
Clearances and Dimensions
1.
Location—Check location where the range will be installed.
Check for proper electrical and gas supply, and the
stability of floor.
2.
Dimensions that are shown must be used.
Given dimensions provide minimum clearance. Contact surface
must be solid and level.
*
33" minimum clearance between the top of the cooking
surface and the bottom of an unprotected wood or
metal cabinet; or 24" minimum when bottom of wood
or metal cabinet is protected by not less than ¼" flame
retardant millboard covered with not less than no.
28 MSG sheet steel, 0.015" stainless steel, 0.024"
aluminum or
0.020" copper. The minimum clearance
is 0" for the rear of the range. Follow all dimension
requirements provided above to prevent property
damage, potential fire hazard, and incorrect countertop
and cabinet cuts.
Avoid locating cabinet storage space above the surface
burners. Avoid locating cabinet storage space above
the surface burners. The absence of cabinets will
eliminate the chance of cabinets catching on fire, and
eliminate the possibility of receiving personal burns
from reaching for the cabinets over flaming surface
burners. If cabinet storage is to be provided, risk can
be reduced by installing a range hood that projects
horizontally a minimum of 5" beyond the bottom of
the cabinets.
DO NOT MAKE ANY ATTEMPT
TO OPERATE THE ELECTRIC IGNITION OVEN
DURING AN ELECTRICAL POWER FAILURE.
RESET ALL OVEN CONTROLS TO OFF IN THE
EVENT OF A POWER FAILURE.
The electric ignitor
will automatically re-ignite the oven burner when
power resumes if the oven thermostat control was
left in the ON position.
When an electrical power failure occurs during use,
the surface burners will continue to operate.
During a power outage, the surface burners can be
lit with a match. Hold a lighted match to the burner,
then slowly turn the knob to the Lite position. Use
extreme caution when lighting burners this way.
Special instructions for appliances installed in the state
of Massachusetts:
This Appliance can only be installed
in the state of Massachusetts by a Massachusetts
licensed plumber or gas fitter. When using a flexible
connector, it must not exceed three (3) feet (36 in.) long.
A "T" handle type manual gas valve must be installed in
the gas supply line to this appliance.
8”
36” Minimum*
30”
Minimum to
wall on either
side of range
above 36” height.
36”
18”
Minimum to
cabinets on
either side
of range
30 1/8”
25” Max.
13”
Maximum depth
for cabinets
above range top.
0” clearance below cooking top and at rear of range
Typical cabinet installation
Front
view
Side
view
Front View
Maximum
Door open
29
7
/
8
"
46"
26"
36
3
/
8
"
±
1
/
4
"