Page 57 highlights
(5) Service clearance area The service clearance area, or the sides which must allow access to the IDD for installation or maintenance, is shown in Figure 4.7. [Surface P'] • Setting terminal (MP model only) • External operator panel connector [Surface P] • Cable connection [Surface R] • Hole for mounting screw [Surface Q] • Hole for mounting screw Figure 4.7 Service clearance area (6) External magnetic field The drive should not be installed near the ferromagnetic body like a speaker to avoid the influence of the external magnetic field. (7) Leak magnetic flux The IDD uses a high performance magnet to achieve a high speed seek. Therefore, a leak magnetic flux at surface of the IDD is large. Mount the IDD so that the leak magnetic flux does not affect to near equipment. (8) Others Seals on the DE prevent the DE inside from the particle. Do not damage or peel off labels. C141-E185 4-7