GE 80-649-3N-XT User Manual - Page 17

Simon XT features - security simon xt

Page 17 highlights

Chapter 2 9 Using the control panel Simon XT features Your Simon XT self-contained security system provides the following features: • Home security • Entry and exit delays • Light control • Emergency • Bypassing sensors • Chime • Latchkey Things you can do The Simon XT features provide you with the ability to perform the following functions: • Arm perimeter (windows and doors) and interior (motion) sensors to indicate intruders. • Control lights to be turned on and off at a set time or if an intruder is detected. • Use one button to send quick response alerts to the central monitoring station. • Access the system from a keyfob that is similar to that used for your car. • Access the system from a remote telephone. • Disable sensors so you can leave a window open while the system is armed. • Get an audio alert when a protected door is opened while the system is disarmed. • Have the system notify you if your children do not arrive at home by a predetermined time. Home security The Simon XT allows you to control which sensors are active at any given time. Table 4 describes the five arming levels that you can set from the control panel. Table 4. Simon XT arming levels Level Function 0 Subdisarm 1 Disarm 2 Arm door and window sensors-exterior 3 Arm motion sensors- interior 4 Arm doors/windows and motion sensors-both Description If your system includes 24-hour protection sensors on items such as gun or jewelry cases, you must subdisarm the panel before accessing these areas to avoid causing an alarm. Environmental sensors, such as smoke and carbon monoxide, stay active at all times. In this level, only 24-hour sensors are active. This level arms the door and window sensors, while leaving the interior motion sensors disarmed. This level allows you to arm the interior motion sensors, while leaving the exterior door and window sensors disarmed. This level allows you to arm all sensors.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58

Chapter 2
Using the control panel
9
Simon XT features
Your Simon XT self-contained security system provides the following features:
Home security
Entry and exit delays
Light control
Emergency
Bypassing sensors
Chime
Latchkey
Things you can do
The Simon XT features provide you with the ability to perform the following functions:
Arm perimeter (windows and doors) and interior (motion) sensors to indicate intruders.
Control lights to be turned on and off at a set time or if an intruder is detected.
Use one button to send quick response alerts to the central monitoring station.
Access the system from a keyfob that is similar to that used for your car.
Access the system from a remote telephone.
Disable sensors so you can leave a window open while the system is armed.
Get an audio alert when a protected door is opened while the system is disarmed.
Have the system notify you if your children do not arrive at home by a predetermined time.
Home security
The Simon XT allows you to control which sensors are active at any given time.
Table 4
describes the five
arming levels that you can set from the control panel.
Table 4.
Simon XT arming levels
Level
Function
Description
0
Subdisarm
If your system includes 24-hour protection sensors on items such as gun or jewelry
cases, you must subdisarm the panel before accessing these areas to avoid causing
an alarm. Environmental sensors, such as smoke and carbon monoxide, stay active at
all times.
1
Disarm
In this level, only 24-hour sensors are active.
2
Arm door and window
sensors—exterior
This level arms the door and window sensors, while leaving the interior motion sensors
disarmed.
3
Arm motion sensors—
interior
This level allows you to arm the interior motion sensors, while leaving the exterior door
and window sensors disarmed.
4
Arm doors/windows and
motion sensors—both
This level allows you to arm all sensors.