GE 80-649-3N-XT User Manual - Page 28
Status beeps
UPC - 782136719079
View all GE 80-649-3N-XT manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 28 highlights
20 Simon XT User Manual Status beeps The panel sounds status beeps to alert you to various system events and conditions. Note: You may receive a different number of status beeps if you press the buttons quickly. Table 7. Status beeps Activity Beep Response Doors + Windows Exit delay and Entry delay beeps sound two times every five seconds and two times per second during the last ten seconds. If silent exit is used, the exit delay beeps will only sound twice when you arm and twice when the exit delay expires. Motions Exit delay and Entry delay beeps sound three times every five seconds and three times per second during the last ten seconds. If silent exit is used, the exit delay beeps will only sound three times when you arm and three times when the exit delay expires. Doors + Windows and Motions Disarm Exit delay and Entry delay beeps sound four times every five seconds and four times per second during the last ten seconds. If silent exit is used, the exit delay beeps will only sound four times when you arm and four times when the exit delay expires. One beep. Chime Two beeps. Special chime Three beeps. Trouble beeps Six beeps every minute. Press STATUS to stop beeps for four hours. No activity beeps a Twenty beeps every minute for five minutes. Feature must be programmed by the installer. a. This feature is not verified for use by UL.