GE AV447FBS Installation Instructions - Page 11
For 3-1-4, Rectangular, For 7, Round Vertical Ducted
View all GE AV447FBS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 11 highlights
Installation Instructions FOR 3-1-4s ;s RECTANGULAR '8&7('',6&+$5*(,167$//$7,216 ONLY: Attach H[KDXVWDGDSWRUGDPSHU over the appropriate knockout opening (for vertical or horizontal, depending on installation) with two exhaust adaptor screws. Make sure damper SLYRW is nearest to WRSEDFNHGJH of hood. Remove WDSH from damper flap. Exhaust adaptor/damper (vertical discharge position) Tape )255(&(66('%27720&$%,1(76 ONLY Wood shims (minimum thickness 3/8s ,IWKHFDELQHWVKDYHIURQWVLGHRUEDFNWULPPDNH 2 wood shims a minimum of 3/8s thick and cut to fit the width of the inner recessed cabinet bottom. Attach them to the cabinet bottom recess on both sides. See Step 11 for marking locations. Pivot (depending on installation) Top/back edge Exhaust adaptor/damper (horizontal discharge position) 9 FOR 7s ROUND VERTICAL DUCTED ',6&+$5*(,167$//$7,21621/