GE GFDR485EFRR Installation Instructions - Page 28
Side Venting Cont., Bottom Venting
View all GE GFDR485EFRR manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 28 highlights
Installation Instructions EXHAUSTING THE DRYER (cont.) SIDE VENTING (cont.) ADDING ELBOW AND DUCT FOR EXHAUST TO LEFT OR RIGHT SIDE OF CABINET (cont.) • Apply duct tape as shown on the joint Duct tape between the dryer internal duct and the elbow, and also the joint between the elbow and the side duct. Use 4" rigid metal ducting only inside the dryer. Internal duct joints must be secured with tape, otherwise they may separate and cause a safety hazard. ADDING COVER PLATE TO REAR OF CABINET (SIDE EXHAUST) Plate (Kit WE1M454) Connect standard metal elbows and ducts to complete the exhaust system. Cover back opening with a plate (Kit WE1M454) available from your local service provider. Place dryer in final location. NEVER LEAVE THE BACK OPENING WITHOUT THE PLATE. (Kit WE1M454.) BOTTOM VENTING: Dryer Exhaust to the bottom of cabinet for Gas and Electric models. WARNING - Electrical Shock Hazard Close the back opening with cover plate (Kit WE1M454). Disconnect dryer from electrical supply. Wear gloves and arm guards. Failure to do so may result in electrical shock or lacerations. Remove screw and save Bottom Remove desired knockout (one only) Remove the screw inside the dryer exhaust duct and save. Pull the duct out of the dryer. Detach and remove the bottom knockout. Fixing hole A 15 3ø4" Cut the duct as shown and keep portion A. 28