GE JGP989 Owners Manual - Page 20

Ductwork Calculations

Page 20 highlights

Installation Instructions DUCTWORK CALCULATIONS Calculate Total Equivalent Ductwork Length Duct Pieces Equivalent Number Equivalent Length* x Used = Length 6″ round straight 1 ft. x ( )† = ft. 31⁄4″ x 10″ straight 1 ft. x ( )† = ft. 6″, 90° elbow 15 ft. x ( ) = ft. Duct Pieces Equivalent Number Equivalent Length* x Used = Length 6″ round to 31⁄4″ x 10″ transition 90° elbow 20 ft. x ( ) = ft. 31⁄4″ x 10″ to 6″ round transition 5 ft. x ( ) = ft. 31⁄4″ x 10″ to 6″ round transition 90° elbow 12 ft. x ( ) = ft. 6″, 45° elbow 9 ft. x ( ) = ft. 6″ round wall cap with damper 21 ft. x ( ) = ft. 24″ max. flexible metal offset adapter 34 ft. x ( ) = ft. 31⁄4″ x 10″ 90° elbow 16 ft. x ( ) = ft. 31⁄4″ x 10″ 45° elbow 5 ft. x ( ) = ft. 31⁄4″ x 10″ 90° flat elbow 18 ft. x ( ) = ft. 31⁄4″ x 10″ wall cap with damper 27 ft. x ( ) = ft. 6″ round roof cap 20 ft. x ( ) = ft. 6″ round roof vent 24 ft. x ( ) = ft. Subtotal Column 2 = ft. Subtotal Column 1 = ft. TOTAL DUCTWORK = ft. 6″ round to 31⁄4″ x 10″ transition 7 ft. x ( ) = Subtotal Column 1 = Should not exceed 100 feet. ft. DO NOT use flexible plastic ducting. Vent installation should not exceed 100 feet ft. equivalent length. *Equivalent lengths of duct pieces are based on actual tests and reflect requirements for good venting performance with any downdraft cooktop. †Measure and list feet of straight duct used. Count and list the quantity of all other duct pieces for the "Number Used" of each type. IMPORTANT: For maximum efficiency, use the shortest and straightest duct run possible, with as few fittings as possible. For satisfactory performance, the duct run should not exceed 100 feet equivalent length. Venting performance is improved by using larger diameter duct. 20

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72

20
Installation Instructions
DUCTWORK CALCULATIONS
Calculate Total Equivalent Ductwork Length
Equivalent
Number
Equivalent
Duct Pieces
Length* x
Used
=
Length
6
round
straight
1 ft.
x
(
)
=
ft.
3
1
±
4
x 10
straight
1 ft.
x
(
)
=
ft.
6
, 90°
elbow
15 ft.
x
(
) =
ft.
6
, 45°
elbow
9 ft.
x
(
)=
ft.
24
max.
flexible
metal offset
adapter
34 ft.
x
(
)=
ft.
3
1
±
4
x 10
90° elbow
16 ft.
x
(
) =
ft.
3
1
±
4
x 10
45° elbow
5 ft.
x
(
)=
ft.
3
1
±
4
x 10
90° flat elbow
18 ft.
x
(
)=
ft.
6
round
to 3
1
±
4
x 10
transition
7 ft.
x
(
) =
ft.
Subtotal Column 1 =
ft.
*Equivalent lengths of duct pieces are based on
actual tests and reflect requirements for good
venting performance with any downdraft cooktop.
†Measure and list feet of straight duct used. Count
and list the quantity of all other duct pieces for the
“Number Used” of each type.
IMPORTANT:
For maximum efficiency, use the shortest and
straightest duct run possible, with as few fittings
as possible.
For satisfactory performance, the duct
run should not exceed 100 feet equivalent length.
Venting performance is improved by using larger
diameter duct.
Equivalent
Number
Equivalent
Duct Pieces
Length* x
Used
=
Length
6
round
to 3
1
±
4
x 10
transition
90° elbow
20 ft.
x
(
) =
ft.
3
1
±
4
x 10
to 6
round
transition
5 ft.
x
(
) =
ft.
3
1
±
4
x 10
to 6
round
transition
90° elbow
12 ft.
x
(
)=
ft.
6
round
wall cap
with damper
21 ft.
x
(
) =
ft.
3
1
±
4
x 10
wall cap
with damper
27 ft.
x
(
) =
ft.
6
round
roof cap
20 ft.
x
(
) =
ft.
6
round
roof vent
24 ft.
x
(
) =
ft.
Subtotal Column 2 =
ft.
Subtotal Column 1 =
ft.
TOTAL DUCTWORK =
ft.
Should not exceed 100 feet.
DO NOT use flexible plastic ducting.
Vent installation should not exceed 100 feet
equivalent length.