GE JGP989 Owners Manual - Page 23

Power Supply Locations

Page 23 highlights

Installation Instructions POWER SUPPLY LOCATIONS GAS SUPPLY: These cooktops are designed to operate on natural gas at 4″ of water column pressure or on LP gas at 10″ of water column pressure. • These cooktops are shipped from the factory set for natural gas. If you decide to use this cooktop with LP gas, conversion adjustments must be made by a service technician or other qualified person. • The pressure regulator must be connected in series with the manifold of the cooktop and must remain in series with the supply line regardless of type of gas being used. For proper operation, the maximum inlet pressure to the regulator must be no more than 10″ water column pressure for natural gas and 14″ water column pressure for LP gas. • When checking the regulator, the inlet pressure must be at least 1″ greater than the regulator output setting. If the regulator is set for 4″ of water column pressure, the inlet pressure must be at least 5″. If the regulator is set for 10″ of water column pressure, the inlet pressure must be at least 11″. For ease of installation, and if local codes permit, the gas supply line into the cooktop should be 1/2″ or 3/4″ ID flexible metal appliance connector, three to five feet long. NOTE: Purchase a new flexible line. DO NOT USE AN OLD PREVIOUSLY USED LINE. • Make gas connection through rear wall, or on cabinet floor at rear, as illustrated. ELECTRICAL SUPPLY: 291⁄2″ 2″ Min 3″ Min CL Gas pipe location Electrical outlet 12″ above cabinet floor (mount on side or back cabinet wall 2″ min. from centerline) 4″ (to clear toe kick area) The built-in gas downdraft cooktop features pilotless electric ignition for energy savings and reliability. It operates on a 120-volt, 60-Hz power supply. A separate circuit, protected by a 15-amp time-delay fuse or circuit breaker, is required. • A properly grounded 3-prong receptacle should be located within reach of cooktop's four foot power cord. IMPORTANT: (Please read carefully.) FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE PROPERLY GROUNDED. The power cord of this appliance is equipped with a three-prong (grounding) plug which mates with a standard threeprong grounding wall receptacle to minimize the possibility of electric shock hazard from this appliance. The customer should have the wall receptacle and circuit checked by a qualified electrician to make sure the receptacle is properly grounded and has correct polarity. Where a standard two-prong wall receptacle is encountered, it is the personal responsibility and obligation of the customer to have it replaced with a properly grounded three-prong wall receptacle. Do Not, Under Any Circumstances, Cut Or Remove The Third (ground) Prong From The Power Cord. Do not use an extension cord. 23

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72

23
Installation Instructions
POWER SUPPLY LOCATIONS
ELECTRICAL SUPPLY:
The built-in gas downdraft cooktop features
pilotless electric ignition for energy savings
and reliability. It operates on a 120-volt,
60-Hz power supply. A separate circuit,
protected by a 15-amp time-delay fuse
or circuit breaker, is required.
A properly grounded 3-prong receptacle
should be located within reach of cooktop’s
four foot power cord.
IMPORTANT: (Please read carefully.) FOR
PERSONAL SAFETY, THIS APPLIANCE MUST
BE PROPERLY GROUNDED.
The power cord of this appliance is
equipped with a three-prong (grounding)
plug which mates with a standard three-
prong grounding wall receptacle to minimize
the possibility of electric shock hazard from
this appliance. The customer should have
the wall receptacle and circuit checked by
a qualified electrician to make sure the
receptacle is properly grounded and
has correct polarity.
Where a standard two-prong wall
receptacle is encountered, it is the personal
responsibility and obligation of the customer
to have it replaced with a properly grounded
three-prong wall receptacle.
Do Not, Under Any Circumstances, Cut Or
Remove The Third (ground) Prong From The
Power Cord.
Do not use an extension cord.
C
L
GAS SUPPLY:
These cooktops are designed to operate on
natural gas at 4
of water column pressure
or on LP gas at 10
of water column
pressure.
These cooktops are shipped from the
factory set for natural gas. If you decide to
use this cooktop with LP gas, conversion
adjustments must be made by a service
technician or other qualified person.
The pressure regulator must be connected in
series with the manifold of the cooktop and
must remain in series with the supply line
regardless of type of gas being used.
For proper operation, the maximum inlet
pressure to the regulator must be no more
than 10
water column pressure for natural
gas and 14
water column pressure for LP
gas.
When checking the regulator, the inlet
pressure must be at least 1
greater than the
regulator output setting. If the regulator is
set for 4
of water column pressure, the inlet
pressure must be at least 5
. If the regulator
is set for 10
of water column pressure, the
inlet pressure must be at least 11
. For ease
of installation, and if local codes permit, the
gas supply line into the cooktop should be
1/2
or 3/4
ID flexible metal appliance
connector, three to five feet long.
NOTE:
Purchase a new flexible line.
DO NOT
USE AN OLD PREVIOUSLY USED LINE.
Make gas connection through rear wall, or
on cabinet floor at rear, as illustrated.
Gas pipe
location
Electrical
outlet 12
above
cabinet floor
(mount on
side or back
cabinet wall
2
min. from
centerline)
3
Min
29
1
±
2
2
Min
4
(to clear toe kick area)