GE JP201CBSS Use and Care Manual - Page 12
Optional installation over GE undersink dishwasher, model GSM 2100.
![]() |
UPC - 084691798118
View all GE JP201CBSS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 12 highlights
Consumer Support Troubleshooting Tips Installation Instructions Care and Cleaning Operating Instructions Safety Instructions Optional installation over GE undersink dishwasher model GSM 2100. (if not installing the cooktop over a dishwasher, go to the next page) Read these instructions completely and carefully. Dimensions and Clearances for Optional Installation 13″ Max. J 13⁄4″ Min. clearance to side wall A: 21 1⁄4″ B: 16 5⁄8″ C: 19 15⁄16″ D: 15 15⁄16″ E: 16 1⁄8″ 30″ Min. F: 20 1⁄8″ G: 10 1⁄16″ H: 3″ J: 2″ Min. K: 3 3⁄4″ Min. A B H D C F G E 13⁄4″ Min. clearance to side wall K 36 ″ Unit and cutout dimensions Floor This counter unit must be installed with the control knobs toward the front edge of the countertop. Counter space must be provided for installation of the counter unit. When choosing the location of the cooktop and dishwasher, consider the following: I When installing over a dishwasher, cooktop models JP200, JP201 and JP202 are only approved for installation over GE Undersink Dishwasher model GSM2100. Install the dishwasher using the separate installation instructions packed with the dishwasher. I The cooktop should be easy to reach and lighted with natural light during the day. I To eliminate the risk of burns or fire by reaching over heated surface units, cabinet storage space located above the surface units should be avoided. If cabinet storage space is to be provided, the risk can be reduced by installing a range hood that projects horizontally a minimum of 5″ beyond the bottom of the cabinets. Cabinets installed above the counter unit may be no deeper than 13″ and must be at least 30″ above the cooktop. I The cooktop must be centered left to right over the dishwasher unit. I To insure accuracy, it is best to make a template when cutting the opening in the counter. See the illustration and chart above for all necessary dimensions. The following minimum clearances must be maintained: I 33⁄4″ minimum clearance between the front edge of the counter unit and the front edge of the counter. I 30 ″ minimum vertical clearance from the cooktop to the nearest overhead surface. I 15 ″ minimum vertical clearance to adjacent cabinets. 12
![](/manual_guide/products/general-electric-jp201cbss-use-care-manual-386b193/12.png)