Genie DirectLift Owner's Manual - Page 10
Fcc And Ic Certified - problems
View all Genie DirectLift manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 10 highlights
MAINTENANCE A Monthly Door springs and door hardware: - Oil door roller, bearings, and hinges using silicone lubricant or light oil. WARNING: Do not operate door automatically or manually if springs are broken. Contact a Genie Factory Authorized Dealer for service or call Customer Service at 1-800-35-GENIE. • Balance Door. - Close door Release Carriage Assembly from Rail Assembly by pulling the Emergency Release Knob towards the door. - Raise door manually 3'- 4' and verify that door stays at that position. See Check Step 2 on page 4. NOTE When the door is 3' - 4' above the ground, the door should stay open. Slight movement is acceptable. If the door moves too much, contact a Genie Factory Authorized Dealer for service or call Customer Service at 1-800-35-GENIE. - Reattach Carriage Assembly to Rail Assembly: a. Pull the Emergency Release Knob toward Power Head. b. Close door. • Contact Reverse Test. - Perform Adjustment 2 on page 8. WARNING: If the door fails to reverse on contact with the board, adjust the Close Force Control as specified in Set Limit Switches and Force Controls on page 7 & 8. If the Opener still fails, contact a Genie Factory Authorized Dealer for service or call Customer Service at 1-800-35-GENIE. B Yearly: • Wipe off old excess lubricant from Drive Screw. • Lubricate Drive Screw with Genie Lubricant (GLU-3) NOTE Use ONLY Genie Lubricant (GLU-3). Other lubricants may damage the Opener. GLU-3 Lubricant FCC AND IC CERTIFIED All devices comply with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. C As needed • Replace lightbulbs. (See page 9) troubleshooting Safe-T-Beam® System Self-Diagnostic Troubleshooting Source (Red LED) Sensor (Green LED) Possible Problem Solution ON ON Normal operation None required OFF OFF • Power Head not powered • Wiring from Power Head bad • Check breakers, fuses, plugs • Check wiring for obvious shorts OFF ON • Wiring to Source missing or bad • Power has been interrupted 2 BLINKS, Pause (Repeat) ON • Beam not aligned • Beam obstructed • Sensor defective 2 BLINKS, Pause (Repeat) OFF • Wire to Sensor missing or bad • Sensor defective 3 BLINKS, Pause • Sensor receiving interference (Repeat) ON 4 BLINKS, Pause (Repeat) ON • Source not sending pulses • Source defective • Check wiring • Remove power and reapply • Check Source, Sensor alignment • Check for obstruction • Contact Customer Service • Check wiring • Contact Customer Service • Determine source of interference • Check for interference from sun- light or a source unit on an adjacent door • Contact Customer Service • Contact Customer Service • Contact Customer Service 10 For Help, call 1-800-35-GENIE or visit www.geniecompany.com