Part A - 4-wire Power Cord
View all Haier HLTD600AEW manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 19 highlights
a Tab A b Strain Relief B 3. Insert a power cord into the strain relief. Take care to ensure that the wire insulation of the power cord is inside the strain relief. 4. Connect power cord wires following Part A for a 4-wire power cord connection or Part B for a 3-wire power cord connection. 4-wire (recommended) if your home has a 4-wire receptacle (NEMA 14-30 type SRDT or ST): 3-wire (if 4-wire is not available) if your home has a 3-wire receptacle (NEMA 10-30 type SRDT): CAUTION: A 4-conductor cord shall be used when the appliance is installed in a location where grounding through the neutral conductor is prohibited. Grounding through the neutral conductor is prohibited for (1) new branch-circuit installations, (2) mobile homes, (3) recreational vehicles, and (4) areas where local codes prohibit grounding through the neutral conductors. 5. Reinstall the terminal block cover. 6. Be sure that none of the wires are touching the dryer drum inside the dryer cabinet. 7. Tighten strain relief screws. PART A - 4-WIRE POWER CORD a d e b f c a Terminal Block Screw b Ground Screw (Green) c Power Cord Ground Wire (Green) d Neutral-Ground Jumper Wire (White) g e Power Cord Line Wires (One Red; One Black) f Power Cord Neutral Wire (White) g Power Cord 17