Haier HPU-18CH13 HPU-123C01 User Manual - Page 28
EI LI
View all Haier HPU-18CH13 HPU-123C01 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 28 highlights
Installation Manual of Room Air Conditioner When piping is longer than 5m, charge additional refrigerant specified in this list. Pipe length 5m 10m 15m Refrigerant charge(g) 90 180 Electric wiring Note: • Electric wiring must be done by qualified person. • Use copper wire only. • The parameter of the electric wiring is HO5VV-F3X2.5mm 2 . Wiring of indoor unit • Insert the cable from outside the wall hole where piping already exist. • Pull it out from front. • Losen terminal screw and insert cable end fully into terminal block, then tighten it • Pull the cable gently to make sure it is tight. • Replace cover after wiring. 11 11 11 11 11 ® ® ® ® O O II Terminal block Wire clip wire loop YEUGRN o OI® WHITE E z po BLU 00 -I 0 BRN } POWER PLUG -Li ()OIT( ) YEUGRN Outdoor unit BLACK Indoor unit Note: User should prepare the part in the dashed frame by himself. Wiring of outdoor unit • Insert the cable from inside the wall hole where piping already exist. • Pull it out from front. • Loose terminal screw and insert cable end fully into terminal block, then tighten it • Pull the cable gently to make sure it is tight. • Replace cover after wiring. Note: • When connecting indoor and outdoor wire, check the number on indoor and outdoor terminal blocks. Terminals of same number and same color shall be connected by the same wire. • Incorrect wiring may damage air conditioner's control or cause operation failure. 27