Haier QFT15ESSNWW Installation Instructions - Page 14

Alcove Or Closet Installation

Page 14 highlights

ENGLISH INSTALLATION INSTRUCTIONS REQUIREMENTS FOR ALCOVE OR CLOSET INSTALLATION WARNING - Explosion Hazard Keep flammable materials and vapors, such as gasoline, away from dryer. Place dryer at least 18" (46 cm) above the floor for a garage installation. Failure to do so can result in death, explosion, or fire. • Minimum clearance between dryer cabinet and adjacent walls or other surfaces is: 0" either side 1" front and rear 1" top • Consideration must be given to provide adequate clearance for installation and service. • Closet doors must be louvered or otherwise ventilated and have at least 60 square inches of open area. If the closet contains both a washer and a dryer, doors must contain a minimum of 120 square inches of open area. MINIMUM CLEARANCE OTHER THAN ALCOVE OR CLOSET INSTALLATION Minimum clearance to combustible surfaces and for air opening are: 0" both sides, 1" rear and 1" top. Consideration must be given to provide adequate clearance for installation and service. MOBILE OR MANUFACTURED HOME INSTALLATION • Installation MUST conform to the MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARD, TITLE 24, PART 3280 or STANDARD FOR MOBILE HOMES CAN/CSA-Z240 MH, or, when such standards are not applicable, with AMERICAN NATIONAL STANDARD FOR MOBILE HOME, ANSI/ NFPA NO. 501B. • Provide an opening with a free area of at least 25 square inches for introduction of outside air into the dryer room. • See the sections for electrical connection information. BATHROOM OR BEDROOM INSTALLATION The installation must conform with local codes or, in the absence of local codes, with the NATIONAL ELECTRICAL CODE, ANSI/NFPA NO. 70 (for electric dryers). UNDERCOUNTER INSTALLATION If an undercounter installation is desired: • No special dryer installation kit is required. • If the dryer is installed alone, a minimum of 60 square inches of open area is required. If a washer and dryer are installed together, a minimum of 120 square inches of open area is required. Dryer Installed Alone Countertop and side cabinets 60 square inches min. open area 120 square inches min. open area Washer and Dryer Installed Together Countertop and side cabinets 14 49-3000193

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84

14
49-3000193
ENGLISH
INSTALLATION INSTRUCTIONS
MOBILE OR MANUFACTURED HOME
INSTALLATION
Installation MUST conform to the MANUFACTURED
HOME CONSTRUCTION AND SAFETY STANDARD,
TITLE 24, PART 3280 or STANDARD FOR MOBILE
HOMES CAN/CSA-Z240 MH, or, when such
standards are not applicable, with AMERICAN
NATIONAL STANDARD FOR MOBILE HOME, ANSI/
NFPA NO. 501B.
Provide an opening with a free area of at least 25
square inches for introduction of outside air into the
dryer room.
See the sections for electrical connection information.
REQUIREMENTS FOR ALCOVE OR
CLOSET INSTALLATION
Keep flammable materials and vapors, such as gasoline,
away from dryer.
Place dryer at least 18” (46 cm) above the floor for a
garage installation.
Failure to do so can result in death, explosion, or fire.
Minimum clearance between dryer cabinet and
adjacent walls or other surfaces is:
0” either side
1” front and rear
1” top
Consideration must be given to provide adequate
clearance for installation and service.
Closet doors must be louvered or otherwise
ventilated and have at least 60 square inches of open
area. If the closet contains both a washer and a dryer,
doors must contain a minimum of 120 square inches
of open area.
MINIMUM CLEARANCE OTHER THAN
ALCOVE OR CLOSET INSTALLATION
Minimum clearance to combustible surfaces and
for air opening are: 0” both sides, 1” rear and 1” top.
Consideration must be given to provide adequate
clearance for installation and service.
- Explosion Hazard
WARNING
UNDERCOUNTER INSTALLATION
If an undercounter installation is desired:
No special dryer installation kit is required.
If the dryer is installed alone, a minimum of 60
square inches of open area is required. If a washer
and dryer are installed together, a minimum of 120
square inches of open area is required.
BATHROOM OR BEDROOM
INSTALLATION
The installation must conform with local codes or,
in the absence of local codes, with the NATIONAL
ELECTRICAL CODE, ANSI/NFPA NO. 70 (for electric
dryers).
60
square
inches
min.
open
area
Dryer Installed Alone
Countertop and side cabinets
Washer and Dryer Installed Together
Countertop and side cabinets
120
square
inches
min.
open
area