Haier QNE27JYMFS Use and Care Manual - Page 29

Performance Data Sheet, Model: Ge Appliances Xwf Water Filter

Page 29 highlights

PERFORMANCE DATA SHEET MODEL: GE APPLIANCES XWF WATER FILTER • System certified by IAPMO R&T against NSF/ANSI Standards 42, 53, 401 for the reduction of claims specified on the performance data sheet and at iapmort.org. • Actual performance may vary with local water conditions. Substance Tested for Reduction Chlorine Taste and Odor Chloramine Taste and Odor Particulate, Class I Cysts Lead Mercury Asbestos Toxaphene VOC (Chloroform surrogate chemical) Alachlor Atrazine Benzene Carbofuran carbon tetrachloride chlorobenzene chloropicrin 2,4-D dibromochloropropane (DBCP) o-Dichlorobenzene p-Dichlorobenzene 1,2-dichloroethane 1,1-dichloroethylene cis-1,2-dichloroethylene trans-1,2-dichloroethylene 1,2-dichloropropane cis-1,3-dichloropropylene dinoseb Endrin Ethylbenzene ethylene dibromide (EDB) bromochloroacetonitrile dibromoacetonitrile dichloroacetonitrile trichloroacetonitrile 1,1-dichloro-2-propanone 1,1,1-trichloro-2-propanone heptachlor (H-34, Heptox) heptachlor epoxide hexachlorobutadiene hexachlorocyclopentadiene Lindane methoxychlor pentachlorophenol simazine Styrene 1,1,2,2-tetrachloroethane Tetrachloroethylene Toluene 2,4,5-TP (silvex) tribromoacetic acid 1,2,4-Trichlorobenzene 1,1,1-trichloroethane 1,1,2-trichloroethane trichloroethylene bromoform bromodichloromethane chlorodibromomethane xylenes Meprobamate Atenolol Carbamazepine DEET Metolachlor Trimethoprim Linuron TCEP TCPP Phenytoin Ibuprofen Naproxen Estrone Bisphenol A Nonyl phenol 49-60806 Rev. 1 ENGLISH Influent challenge concentration (mg/L) 2.0 mg/L +/- 10% 3.0 mg/L +/- 10% At least 10,000/mL 50,000/L 0.15 0.006 107 to 108 fibers/ L 0.015 +/- 10% 0.300 0.050 0.100 0.081 0.190 0.078 0.077 0.015 0.110 0.052 0.08 0.040 0.088 0.083 0.170 0.086 0.080 0.079 0.170 0.053 0.088 0.044 0.022 0.024 0.0096 0.015 0.0072 0.0082 0.025 0.0107 0.044 0.060 0.055 0.050 0.096 0.120 0.150 0.081 0.081 0.078 0.270 0.042 0.160 0.084 0.150 0.180 0.300 0.300 0.300 0.070 400 +/- 20% 200 +/- 20% 1400 +/- 20% 1400 +/- 20% 1400 +/- 20% 140 +/- 20% 140 +/- 20% 5000 +/- 20% 5000 +/- 20% 200 +/- 20% 400 +/- 20% 140 +/- 20% 140 +/- 20% 2000 +/- 20% 1400 +/- 20% Maximum permissible product water concentration (mg/L) N/A 0.5 N/A N/A 0.01 0.002 N/A 0.003 0.015 0.001 0.003 0.001 0.001 0.0018 0.001 0.0002 0.0017 0.00002 0.001 0.001 0.0048 0.001 0.0005 0.001 0.001 0.001 0.0002 0.00059 0.001 0.00002 0.0005 0.0006 0.0002 0.0003 0.0001 0.0003 0.00001 0.0002 0.001 0.000002 0.00001 0.0001 0.001 0.004 0.0005 0.001 0.001 0.001 0.0016 0.001 0.0005 0.0046 0.0005 0.0010 0.015 0.015 0.015 0.001 60 30 200 200 200 20 20 700 700 30 60 20 20 300 200 Avg % Reduction 96.9 96.9 91.4 >99.99 98.85 96.3 >99 86.95 99.7 > 98 > 97 > 99 > 99 98 > 99 99 98 > 99 > 99 > 98 95 > 99 > 99 > 99 > 99 > 99 99 99 > 99 > 99 98 98 98 98 99 96 >99 98 > 98 > 99 > 99 > 99 > 99 > 97 > 99 > 99 > 99 > 99 99 > 98 > 99 95 > 99 > 99 95 95 95 >99 95.5 95.9 98.6 98.6 98.7 96.1 96.6 98.1 98.1 96 95.9 96.5 97.1 99.1 97.3 Application Guidelines/Water Supply Parameters Service Flow Water Supply Water Pressure Water Temperature Capacity 0.5 gpm (1.89 lpm) Potable Water 25-120 psi (172-827 kPa) 33°F-100°F (0.6°C-38°C) 170 gallons (643.5 liters) It is essential that the manufacturer's recommended installation, maintenance and filter replacement requirements be carried out for the product to perform as advertised. See Installation Manual for Warranty information. Note: While the testing was performed under standard laboratory conditions, actual performance may vary. Replacement Cartridge: XWF. For estimated costs of replacement elements please call 877.337.3639 or visit our website at HaierParts.com WARNING To reduce the risk associated with ingestion of contaminants: • Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before and after the system. Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts. NOTICE To reduce the risk of water leakage or flooding, and to ensure optimal filter performance: • Read and follow use instructions before installation and use of this system. • Installation and use MUST comply with all state and local plumbing codes. • Do not install if water pressure exceeds 120 psi (827 kPa). If your water pressure exceeds 80 psi (552 kPa), you must install a pressure-limiting valve. Contact a plumbing professional if you are uncertain how to check your water pressure. • Do not install where water hammer conditions may occur. If water hammer conditions exist you must install a water hammer arrester. Contact a plumbing professional if you are uncertain how to check for this condition. • Do not install on hot water supply lines. The maximum operating water temperature of this filter system is 100º F (38º C). • Protect filter from freezing. Drain filter when temperatures drop below 33ºF (0.6ºC). • Change the disposable filter cartridge every six months or sooner if you observe a noticeable reduction in water flow rate. • Failure to replace the disposable filter cartridge at recommended intervals may lead to reduced filter performance and cracks in the filter housing, causing water leakage or flooding. • This System has been tested according to NSF/ANSI 42, 53 and 401 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42, 53 and 401. XWF System is certified by IAPMO R&T against NSF/ANSI Standards 42,53, and 401 for the reduction of claims specified on the performance data sheet and at iapmort.org. 29

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88

PERFORMANCE DATA SHEET
MODEL: GE APPLIANCES XWF WATER FILTER
System certified by IAPMO R&T against NSF/ANSI Standards 42, 53, 401 for the reduction of claims specified on the performance data sheet and
at iapmort.org.
• Actual performance may vary with local water conditions.
It is essential that the manufacturer’s recommended installation,
maintenance and filter replacement requirements be carried out for the
product to perform as advertised. See Installation Manual for Warranty
information.
Application Guidelines/Water Supply Parameters
Service Flow
0.5 gpm
(1.89 lpm)
Water Supply
Potable Water
Water Pressure
25-120 psi (172-827 kPa)
Water Temperature
33°F-100°F (0.6°C-38°C)
Capacity
170 gallons (643.5 liters)
Substance Tested for Reduction
Influent challenge
concentration
(mg/L)
Maximum permissible
product water
concentration (mg/L)
Avg %
Reduction
Chlorine Taste and Odor
2.0 mg/L +/- 10%
N/A
96.9
Chloramine Taste and Odor
3.0 mg/L +/- 10%
0.5
96.9
Particulate, Class I
At least 10,000/mL
N/A
91.4
Cysts
50,000/L
N/A
>99.99
Lead
0.15
0.01
98.85
Mercury
0.006
0.002
96.3
Asbestos
107 to 108
fibers/ L
N/A
>99
Toxaphene
0.015 +/- 10%
0.003
86.95
VOC (Chloroform surrogate chemical)
0.300
0.015
99.7
Alachlor
0.050
0.001
> 98
Atrazine
0.100
0.003
> 97
Benzene
0.081
0.001
> 99
Carbofuran
0.190
0.001
> 99
carbon tetrachloride
0.078
0.0018
98
chlorobenzene
0.077
0.001
> 99
chloropicrin
0.015
0.0002
99
2,4-D
0.110
0.0017
98
dibromochloropropane (DBCP)
0.052
0.00002
> 99
o-Dichlorobenzene
0.08
0.001
> 99
p-Dichlorobenzene
0.040
0.001
> 98
1,2-dichloroethane
0.088
0.0048
95
1,1-dichloroethylene
0.083
0.001
> 99
cis-1,2-dichloroethylene
0.170
0.0005
> 99
trans-1,2-dichloroethylene
0.086
0.001
> 99
1,2-dichloropropane
0.080
0.001
> 99
cis-1,3-dichloropropylene
0.079
0.001
> 99
dinoseb
0.170
0.0002
99
Endrin
0.053
0.00059
99
Ethylbenzene
0.088
0.001
> 99
ethylene dibromide (EDB)
0.044
0.00002
> 99
bromochloroacetonitrile
0.022
0.0005
98
dibromoacetonitrile
0.024
0.0006
98
dichloroacetonitrile
0.0096
0.0002
98
trichloroacetonitrile
0.015
0.0003
98
1,1-dichloro-2-propanone
0.0072
0.0001
99
1,1,1-trichloro-2-propanone
0.0082
0.0003
96
heptachlor (H-34, Heptox)
0.025
0.00001
>99
heptachlor epoxide
0.0107
0.0002
98
hexachlorobutadiene
0.044
0.001
> 98
hexachlorocyclopentadiene
0.060
0.000002
> 99
Lindane
0.055
0.00001
> 99
methoxychlor
0.050
0.0001
> 99
pentachlorophenol
0.096
0.001
> 99
simazine
0.120
0.004
> 97
Styrene
0.150
0.0005
> 99
1,1,2,2-tetrachloroethane
0.081
0.001
> 99
Tetrachloroethylene
0.081
0.001
> 99
Toluene
0.078
0.001
> 99
2,4,5-TP (silvex)
0.270
0.0016
99
tribromoacetic acid
0.042
0.001
> 98
1,2,4-Trichlorobenzene
0.160
0.0005
> 99
1,1,1-trichloroethane
0.084
0.0046
95
1,1,2-trichloroethane
0.150
0.0005
> 99
trichloroethylene
0.180
0.0010
> 99
bromoform
0.300
0.015
95
bromodichloromethane
0.300
0.015
95
chlorodibromomethane
0.300
0.015
95
xylenes
0.070
0.001
>99
Meprobamate
400 +/- 20%
60
95.5
Atenolol
200 +/- 20%
30
95.9
Carbamazepine
1400 +/- 20%
200
98.6
DEET
1400 +/- 20%
200
98.6
Metolachlor
1400 +/- 20%
200
98.7
Trimethoprim
140 +/- 20%
20
96.1
Linuron
140 +/- 20%
20
96.6
TCEP
5000 +/- 20%
700
98.1
TCPP
5000 +/- 20%
700
98.1
Phenytoin
200 +/- 20%
30
96
Ibuprofen
400 +/- 20%
60
95.9
Naproxen
140 +/- 20%
20
96.5
Estrone
140 +/- 20%
20
97.1
Bisphenol A
2000 +/- 20%
300
99.1
Nonyl phenol
1400 +/- 20%
200
97.3
Note:
While the testing was performed under standard
laboratory conditions, actual performance may vary.
Replacement Cartridge: XWF. For estimated costs of
replacement elements please call 877.337.3639 or visit our
website at
HaierParts.com
WARNING
To reduce the risk associated with
ingestion of contaminants:
Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before and
after the system.
Systems certified for cyst reduction may be
used on disinfected water that may contain filterable cysts.
NOTICE
To reduce the risk of water leakage or flooding, and to
ensure optimal filter performance:
Read and follow
use instructions before installation and use of
this system.
Installation and use
MUST
comply with all state and local
plumbing codes.
Do not
install if water pressure exceeds 120 psi (827 kPa). If
your water pressure exceeds 80 psi (552 kPa), you
must
install
a pressure-limiting valve. Contact a plumbing professional if
you are uncertain how to check your water pressure.
Do not
install where water hammer conditions may occur.
If water hammer conditions exist you
must
install a water
hammer arrester. Contact a plumbing professional if you are
uncertain how to check for this condition.
Do not
install on hot water supply lines. The maximum
operating water temperature of this filter system is 100º F
(38º C).
Protect filter from freezing.
Drain filter when temperatures
drop below 33ºF (0.6ºC).
Change the disposable filter cartridge every six months or
sooner
if you observe a noticeable reduction in water flow
rate.
Failure to replace the disposable filter cartridge at
recommended intervals may lead to reduced filter
performance and cracks in the filter housing, causing water
leakage or flooding.
This System has been tested according to NSF/ANSI 42, 53
and 401 for the reduction of the substances listed below. The
concentration of the indicated substances in water entering
the system was reduced to a concentration less than or
equal to the permissible limit for water leaving the system, as
specified in NSF/ANSI 42, 53 and 401.
XWF System is certified by IAPMO R&T
against NSF/ANSI Standards 42,53, and 401
for the reduction of claims specified on the
performance data sheet and at iapmort.org.
49-60806
Rev. 1
29
ENGLISH