Harbor Freight Tools 61454 User Manual - Page 13

Emergency Depressurization, Automatic Shut off System

Page 13 highlights

SAFETY Emergency Depressurization If it is necessary to quickly depressurize the Compressor, turn the Power Switch OFF. Then, pull on the ring on the Safety Valve to quickly release stored air pressure. Automatic Shut off System Reset Button Figure I: Reset Button 1. If the Compressor automatically shuts off before reaching its normal cutoff pressure: a. Shut off all tools. b. Wait until the Compressor cools down (about 10 minutes); c. If the unit does not start up again on its own, press the Reset Button to start the compressor; d. Resume operation. 2. Possible causes of repeated automatic shut off of the compressor are: a. Using an extension cord that is too long or narrow; b. An air leak or open hose causing the compressor to cycle too often and build up heat. 3. Correct any issues before further use to avoid damage to the compressor. SETUP OPERATION MAINTENANCE Item 61454 For technical questions, please call 1-800-444-3353. Page 13

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

Page 13
For technical questions, please call 1-800-444-3353.
Item 61454
Emergency Depressurization
If it is necessary to quickly
depressurize
the Compressor, turn the Power Switch OFF.
Then, pull on the ring on the Safety Valve to quickly release stored air pressure.
Automatic Shut off System
Reset
Button
Figure I:
Reset Button
1.
If the Compressor automatically shuts off
before reaching its normal cutoff pressure:
a.
Shut off all tools.
b.
Wait until the Compressor cools down
(about 10 minutes);
c.
If the unit does not start up again on its own,
press the Reset Button to start the compressor;
d.
Resume operation.
2.
Possible causes of repeated automatic
shut off of the compressor are:
a.
Using an extension cord that is too long or narrow;
b.
An air leak or open hose causing the compressor
to cycle too often and build up heat.
3.
Correct any issues before further use to
avoid damage to the compressor.
SAFETY
OPERATION
MAINTENANCE
SETUP