Harbor Freight Tools 61614 User Manual - Page 14
Battery Setup Instructions
View all Harbor Freight Tools 61614 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 14 highlights
SAFETY Battery Setup Instructions 1. Place a fully charged, lead-acid 12 volt, 36 Ah battery (not included) in a stable, flat location near the engine. solenoid on Starter (164) 2. Only use cables sized to match their length according to . Cable Gauge (lower gauge numbers mean thicker cables) Maximum Cable Length 6 5′ 4 7′ 2 12′ Table A: Minimum Cable Diameters 3. Attach the positive cable from the positive battery terminal to the outer terminal on the Starter's (164) solenoid, see Figure Q and Figure R. Connect cable securely to prevent disconnection and short circuits. 4. Attach the negative cable to the negative battery terminal. 5. Connect the negative cable securely to one of the engine mounting bolts, as shown in Figure Q. Connect cable securely to prevent disconnection and short circuits. red wire to positive battery cable connect negative battery cable to a mounting bolt Figure Q: Battery Cable Connections Connect Cable from positive Battery Terminal to this Starter Terminal 6. Coat the terminals and cable ends with a corrosion-preventive coating. Figure R: Connect positive to this Terminal SETUp OpERATION MAINTENANCE Page 14 For technical questions, please call 1-888-866-5797. ITEM 61614