Hayward AquaRite S3 Omni Salt System 40 000 gallon AQRS3-Omni-Series-Automatio - Page 31

Service Mode and Firmware Upgrade

Page 31 highlights

Service Mode and Firmware Upgrade Service Mode Service Mode is used for upgrading firmware, service maintenance and diagnostic functions. Note that changes within Service mode should only be made by qualified individuals who understand the connected pool equipment. Because systems will be disabled while in Service Mode, you will have an option to set a timer before entering. Because most functions in Service Mode require a qualified service professional, a brief overview is shown below. You may be asked by Hayward Technical Service to access some of these functions to provide information or help diagnose an issue. LVR This function allows technicians to energize/de-energize the connected low voltage relays. HVR This function allows technicians to energize/de-energize the connected high voltage relays. Valve This function allows technicians to energize/de-energize the connected valves. Sensor View and calibrate connected temperature sensors. Chlorinator View diagnostic information and test the chlorinator function. VSP View diagnostic information and test connected VSPs. CS&D View diagnostic information and test Sense and Dispense equipment. Config Some of the Config options operate differently while in Service Mode. There are also additional Config options available in Service Mode that are not shown in Standard Mode. Backup - While in Service Mode, Backup adds a third option called "Clone Controller to USB". This would most likely be used by service personnel who are replacing the mainboard in the AQR S3 Omni. This Clone option will allow for a mirror image of the AQR S3 Omni's configuration, settings, and attached devices to be written to a USB thumb drive. After the mainboard is replaced, the AQR S3 Omni can be restored to all of the original parameters. Only one clone file can be copied to a USB drive and this option shouldn't be used to copy an image to other AQR S3 Omnis. For those applications, one should use the standard backup function (page 29). Wireless Waterproof - This option displays the HUA of each connected waterproof remote control and allows you to enable or disable the units. SC upload files - This option can be used to upload files to Hayward Technical Service for evaluation and troubleshooting. Web Server - This is for internal use only. Boot Image - A copy of the unit's operating system is kept on internal storage in case of file corruption. If necessary, Hayward Technical Service may instruct you to use this option. 30 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
30
Service Mode and Firmware Upgrade
Service Mode
Service Mode is used for upgrading firmware, service maintenance and diagnostic functions. Note
that changes within Service mode should only be made by qualified individuals who understand the
connected pool equipment. Because systems will be disabled while in Service Mode, you will have
an option to set a timer before entering.
Because most functions in Service Mode require a qualified service professional, a brief overview is
shown below. You may be asked by Hayward Technical Service to access some of these functions to
provide information or help diagnose an issue.
LVR
This function allows technicians to energize/de-energize the connected low voltage
relays.
HVR
This function allows technicians to energize/de-energize the connected high voltage
relays.
Valve
This function allows technicians to energize/de-energize the connected valves.
Sensor
View and calibrate connected temperature sensors.
Chlorinator
View diagnostic information and test the chlorinator function.
VSP
View diagnostic information and test connected VSPs.
CS&D
View diagnostic information and test Sense and Dispense equipment.
Config
Some of the Config options operate differently while in Service Mode. There are also
additional Config options available in Service Mode that are not shown in Standard
Mode.
Backup
- While in Service Mode, Backup adds a third option called “Clone
Controller to USB”. This would most likely be used by service personnel who are
replacing the mainboard in the AQR S3 Omni. This Clone option will allow for a
mirror image of the AQR S3 Omni’s configuration, settings, and attached devices
to be written to a USB thumb drive. After the mainboard is replaced, the AQR S3
Omni can be restored to all of the original parameters. Only one clone file can
be copied to a USB drive and this option shouldn’t be used to copy an image
to other AQR S3 Omnis. For those applications, one should use the standard
backup function (page 29).
Wireless Waterproof
- This option displays the HUA of each connected water-
proof remote control and allows you to enable or disable the units.
SC upload files
- This option can be used to upload files to Hayward Technical
Service for evaluation and troubleshooting.
Web Server
-
This is for internal use only.
Boot Image
- A copy of the unit’s operating system is kept on internal storage
in case of file corruption. If necessary, Hayward Technical Service may instruct
you to use this option.