Hayward Ecommand W/2Gva/Base/Aquaconne ECOMMAND-4-Operation-Manual-092420ARevF
Hayward Ecommand W/2Gva/Base/Aquaconne Manual
View all Hayward Ecommand W/2Gva/Base/Aquaconne manuals
Add to My Manuals
Save this manual to your list of manuals |
Hayward Ecommand W/2Gva/Base/Aquaconne manual content summary:
- Hayward Ecommand W/2Gva/Base/Aquaconne | ECOMMAND-4-Operation-Manual-092420ARevF - Page 1
092420A RevF ECOMMAND 4 Automation Operation Manual \ Contents Introduction 2 Operation 3 How-To Guide 24 Troubleshooting 26 Warranty 30 HPC-4 HPC-4-ACT HPC-4-RC HPC-4-ACT-RC HPC-4-S HPC4-AQC HPC4-ACT-AQC Hayward Industries 400 Connell Drive, Suite 6100 Berkeley - Hayward Ecommand W/2Gva/Base/Aquaconne | ECOMMAND-4-Operation-Manual-092420ARevF - Page 2
be followed, including the following: • READ AND FOLLOW ALL INSTRUCTIONS • WARNING: Disconnect all AC power during installation. • WARNING: must be connected to the grounding means provided in the electric supply service panel with a continuous copper wire equivalent in size to the circuit - Hayward Ecommand W/2Gva/Base/Aquaconne | ECOMMAND-4-Operation-Manual-092420ARevF - Page 3
pumps, valves, lighting, heaters, and chlorination. Although the ECOMMAND 4 is easy to use, it is important to completely read through this operating manual before attempting to operate the control. Optional Wireless Spaside Remote G LD LINE C O NTRO LS INC . POOL VALVES SPA ON FILTER OFF ON - Hayward Ecommand W/2Gva/Base/Aquaconne | ECOMMAND-4-Operation-Manual-092420ARevF - Page 4
turn off and follow the normal program from then on. Manually turning off a relay works in a similar fashion. Display Heater Indicator Valve 3 Indicator Check System Indicator Service Button (main display only) Salt Level 3200ppm Service Pool/Spa Filter Lights Aux 1 Aux 2 Pool/Spa Button (Pool - Hayward Ecommand W/2Gva/Base/Aquaconne | ECOMMAND-4-Operation-Manual-092420ARevF - Page 5
to circulate the water. Lights, Aux1 and Aux2 Outputs Standard Relay: Manual operation of all 3 relays is identical. Assuming that the relay is to normal operation. When the Lights or Aux output comes on again (either manually or automatically), the dimmer output level will be the same as the last - Hayward Ecommand W/2Gva/Base/Aquaconne | ECOMMAND-4-Operation-Manual-092420ARevF - Page 6
SERVICE button again, will return the ECOMMAND 4 to normal (automatic) operation. See Troubleshooting/Diagnostic Information (page 26) for more information about the service pool and spa temperatures can be programmed. This section will guide you on how to program the automatic operation for each - Hayward Ecommand W/2Gva/Base/Aquaconne | ECOMMAND-4-Operation-Manual-092420ARevF - Page 7
included in both the Operation and the Installation Manual. The "Diagnostic Menu" is primarily intended for the service technician and contains information and details about the system operation that are helpful in troubleshooting, if problems occur. 6 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS - Hayward Ecommand W/2Gva/Base/Aquaconne | ECOMMAND-4-Operation-Manual-092420ARevF - Page 8
salt level reason pump is running (not scheduled) reason hi-speed is running (not scheduled) countdown time remaining heater control status system manual off check system error filter speed settings menu spa heater1 temperature pool heater1 temperature spa solar temperature pool solar temperature - Hayward Ecommand W/2Gva/Base/Aquaconne | ECOMMAND-4-Operation-Manual-092420ARevF - Page 9
Settings Menu The Settings Menu allows you to set all system operating parameters except the timeclock and countdown timers which are part of the Timers Menu. Spa Heater1 Off Adjust the desired spa temperature (Off, 65°F, 66°F, ...103°F, 104°F, Off) Move to previous/next menu item The spa heater - Hayward Ecommand W/2Gva/Base/Aquaconne | ECOMMAND-4-Operation-Manual-092420ARevF - Page 10
the normal filter pump timeclock settings. At the end of the super chlorinate period, the pool will return to normal operation. If you manually turn off the filter pump (using the FILTER button on any display/keypad), the super chlorinate function terminates. When you turn the filter pump - Hayward Ecommand W/2Gva/Base/Aquaconne | ECOMMAND-4-Operation-Manual-092420ARevF - Page 11
display/keypad that you are currently using. You need to set this option for each display/keypad in your system. NOTE: This function is not supported on all display/keypads. If the "Enabled" selection is not blinking, then the current software revision of that particular keypad/display does not - Hayward Ecommand W/2Gva/Base/Aquaconne | ECOMMAND-4-Operation-Manual-092420ARevF - Page 12
Teach Wireless + to start Press and hold wireless button Teach Wireless Successful Teach Wireless NOT Successful Teach Wireless Base NOT Found Push to start process Move to previous/next menu item Press any button on wireless remote Move to previous/next menu item Move to previous/next menu item - Hayward Ecommand W/2Gva/Base/Aquaconne | ECOMMAND-4-Operation-Manual-092420ARevF - Page 13
reasons the filter pump may be running at times other than the timeclock period set above. These include super chlorinate, spa operation, manual operation, heater cooldown, freeze protection and "solar-extend". SetFiDltaeyr aTn2d-aTlilme W8ed:3n0eAsdtaoy 41:00:03P7P or Filter T2-wkend 8:30A to - Hayward Ecommand W/2Gva/Base/Aquaconne | ECOMMAND-4-Operation-Manual-092420ARevF - Page 14
heat the spa up to the programmed spa temperature (page 8). This programmed spa operation will take precedence over all other automatic functions, only manual operation of the filter button or pool/spa valve button will override this function. If your pool has a separate jet pump or blower - Hayward Ecommand W/2Gva/Base/Aquaconne | ECOMMAND-4-Operation-Manual-092420ARevF - Page 15
This menu will appear only if Valve3 is configured for timeclock. The valve will rotate on and off at the designated times. There is no manual override. If the Valve3 relay is on during the programmed off time, it may be because of freeze protection. Super Chlorinate 24 hours Adjust - Hayward Ecommand W/2Gva/Base/Aquaconne | ECOMMAND-4-Operation-Manual-092420ARevF - Page 16
operation. Spa CountDn This menu will appear only if Pool/Spa Setup is set to "Pool and Spa". This setting is the time, after you manually switch the Pool/Spa valves to "Spa Only", until the ECOMMAND 4 automatically returns the valves to their previous positions. It is programmed in increments of - Hayward Ecommand W/2Gva/Base/Aquaconne | ECOMMAND-4-Operation-Manual-092420ARevF - Page 17
the AUX relays must also be configured to control the low speed motor winding on the pump. Refer to the appropriate sections in the Installation manual for specific information regarding the control logic for 2-speed and variable speed pump operation. 16 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS - Hayward Ecommand W/2Gva/Base/Aquaconne | ECOMMAND-4-Operation-Manual-092420ARevF - Page 18
For the Hayward Tristar variable speed pump: The Filter relay is used to supply input power to the VSC pump control. The relay will be on when the filter pump output is on. When the filter pump output is off, the relay will be off. On, off and speed is controlled by commands sent to the pump. Lowest - Hayward Ecommand W/2Gva/Base/Aquaconne | ECOMMAND-4-Operation-Manual-092420ARevF - Page 19
Heater Cooldown This feature ensures that the heater cools down before water circulation is stopped. When enabled, the ECOMMAND 4 will continue to run the filter pump for 5 minutes after the heater turns off. During this period the filter pump LED will flash and also a "Heater Cooldown, X:XX - Hayward Ecommand W/2Gva/Base/Aquaconne | ECOMMAND-4-Operation-Manual-092420ARevF - Page 20
used, the lights relay can be used to control other pool devices that may require these options. The function of each option is shown below. Manual On/Off (default) - the lights relay will alternate between turning on and off when the LIGHTS button is pressed. There is no automatic control logic - Hayward Ecommand W/2Gva/Base/Aquaconne | ECOMMAND-4-Operation-Manual-092420ARevF - Page 21
for the lights timeclock in the Timers Menu (see Timers Menu in Operation Manual). The LIGHTS button can also be used to turn the output on and if "Dimmer" is desired. When "Dimmer" is selected, and the Lights output is manually turned on, the "+" and "-" buttons adjust the level from 20% to 100% - Hayward Ecommand W/2Gva/Base/Aquaconne | ECOMMAND-4-Operation-Manual-092420ARevF - Page 22
- the aux relay will turn on when the AUX button is pressed and then will turn off automatically after a programmed time (see Timers Menu, Operation Manual). The AUX button can also be used to turn the output off. Low Speed of a 2-speed Filter Pump - the ECOMMAND 4 will operate the aux relay - Hayward Ecommand W/2Gva/Base/Aquaconne | ECOMMAND-4-Operation-Manual-092420ARevF - Page 23
menu Valve3 Function Timeclock (default) - the valve turns on/off at the times set for the valve3 timeclock in the Timers Menu (see Operations Manual). Solar - the valve operates when the filter pump is running, solar heat is available, and the water is less than the desired temperature setting - Hayward Ecommand W/2Gva/Base/Aquaconne | ECOMMAND-4-Operation-Manual-092420ARevF - Page 24
Valve3=Aux1 - the valve operates whenever the Aux1 relay is on. Valve3=Aux2 - the valve operates whenever the Aux2 relay is on. Valve3 Interlock If "Enabled", this feature will override the function (timeclock or in-floor cleaner) selected above and turn the valve off when: the filter pump is off, - Hayward Ecommand W/2Gva/Base/Aquaconne | ECOMMAND-4-Operation-Manual-092420ARevF - Page 25
configuration and reset all configuration parameters back to the factory default values. This function is NOT reversible--be careful. Quick "How To" Guide Operate the Spa-Manually 1. Press the "Pool/Spa" button to go to "spa-only" operation (right LED illuminated). In some cases, this may take more - Hayward Ecommand W/2Gva/Base/Aquaconne | ECOMMAND-4-Operation-Manual-092420ARevF - Page 26
is still permitted. There may be other automatic or manual operations that prevent the relay/valve from operating-see a more detailed discussion under Automatic System Operation/Timers Menu/Aux Timeclock or in Troubleshooting/Diagnostic Information. 25 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS - Hayward Ecommand W/2Gva/Base/Aquaconne | ECOMMAND-4-Operation-Manual-092420ARevF - Page 27
the end of the 3 hour time period. Troubleshooting The ECOMMAND 4 provides 2 different tools to aid in troubleshooting any problems that may occur in your pool and/or spa system. The Service mode will allow you to disable automatic operation and manually control most of the equipment (the heater and - Hayward Ecommand W/2Gva/Base/Aquaconne | ECOMMAND-4-Operation-Manual-092420ARevF - Page 28
selected for the Pool Filter and the Hayward VSC is indicating an error. x is the same decimal error displayed by the VSC itself. For helpful troubleshooting information on any of these issues, go to the Diagnostic Menu and then scroll through the various items until you see the cause for the - Hayward Ecommand W/2Gva/Base/Aquaconne | ECOMMAND-4-Operation-Manual-092420ARevF - Page 29
Test Minerals) Refer to the Aqua Rite or Swimpure manual to correct error. Water Sensor Open circuit Air Sensor the placement of the sensor. If the problem is not placement related, then the sensor will configuration. If you call the Hayward Technical Service Dept. for assistance, they may ask for - Hayward Ecommand W/2Gva/Base/Aquaconne | ECOMMAND-4-Operation-Manual-092420ARevF - Page 30
29 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS - Hayward Ecommand W/2Gva/Base/Aquaconne | ECOMMAND-4-Operation-Manual-092420ARevF - Page 31
Hayward authorized warranty service center. For more information on authorized service centers please contact the Hayward Technical Service Support Center (61 Whitecap in accordance with the recommendations in the owners manual(s). 5. Problems resulting from tampering, accident, abuse, negligence, - Hayward Ecommand W/2Gva/Base/Aquaconne | ECOMMAND-4-Operation-Manual-092420ARevF - Page 32
For further information or consumer technical support, visit our website at www.hayward.com Hayward is a registered trademark and ECOMMAND 4 is a trademark of Hayward Industries, Inc. © 2019 Hayward Industries, Inc. All other
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
\
ECOMMAND 4
Automation
Operation Manual
092420A RevF
HPC-4
HPC-4-ACT
HPC-4-RC
HPC-4-ACT-RC
HPC-4-S
HPC4-AQC
HPC4-ACT-AQC
Contents
Introduction
...............................
2
Operation
...................................
3
How-To Guide
...........................
24
Troubleshooting
.......................
26
Warranty
..................................
30
Hayward Industries
400 Connell Drive, Suite 6100
Berkeley Heights, NJ 07922
Phone: (908) 355-7995
www.hayward.com