Hayward Ecommand W/2Gva/Base/Aquaconne ECOMMAND-4-Operation-Manual-092420ARevF - Page 23
If Enabled, this feature will override the function Manual On/Off, Countdown Timer
View all Hayward Ecommand W/2Gva/Base/Aquaconne manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 23 highlights
Aux1 Interlock If "Enabled", this feature will override the function (Manual On/Off, Countdown Timer, Timeclock), selected above and turn the aux1 off when: filter pump is off, first 3 minutes of filter pump operation (allows the pump to prime and get water flowing), when the pool/spa suction return valves are in any position other than "pool only", or for the first 3 minutes after solar turns on (allows air in the solar panels to be purged). Interlock is not available for solar, low speed filter pump, super chlorinate or dimmer. Aux1 Freeze Protection This function protects the pool, plumbing, and equipment against freeze damage. If Freeze Protection is enabled and the AIR temperature falls below the selected freeze temperature threshold, the ECOMMAND 4 will turn on the aux relay to circulate the water. IMPORTANT: this only enables operation of the AUX output during freeze--see the "Filter Pump Config." menu to enable freeze protection for the main circulation system. Aux1 Pump Speed This is the speed of the pump when the Aux1 output is on. The choices are the Settings Menu speed and a speed that is unique to the Aux1 output only. The default selection is in the "Settings Menu". This is the speed of the pump that has been selected in the Settings Menu for normal filter operation. If an alternate speed is desired when the Aux1 output is on, push "+" or "-" and select from "Lowest" to "Highest" in 5% increments. Valve3 Config. + to view/change Push to access Valve3 options Move to previous/next configuration menu Valve3 Function Solar Rotates between Timeclock (default), Solar, In-floor Cleaner, Filter, Lights, Aux1 and Aux2 Move to next menu item for all functions except solar and super chlorinate Valve3 Interlock Toggle between Enabled and Disabled (default) Valve3 Interlock Disabled Move to next menu item for all functions except super chlorinate Valve3 Freeze Toggle between Enabled and Disabled (default) Valve3 Freeze Disabled Move to previous/next configuration menu only if filter pump is set to variable and relay type is set to standard Valve3 Pump Spd Settings Menu Select between Settings Menu (default) and the desired pump speed Move to previous/next configuration menu Valve3 Function Timeclock (default) - the valve turns on/off at the times set for the valve3 timeclock in the Timers Menu (see Operations Manual). Solar - the valve operates when the filter pump is running, solar heat is available, and the water is less than the desired temperature setting. Solar heating must be enabled in the "Solar Config." menu for proper operation to occur. In-Floor Cleaner - the valve switches the water returning to the pool between the in-floor cleaner and the normal return jets which facilitate efficient surface skimming. The valve will operate the in-floor cleaner for the first half of each clock hour and then switch to the jets/skimming for the last half of the hour. Valve3=Filter - the valve operates whenever the Filter relay is on. Valve3=Lights - the valve operates whenever the Lights relay is on. 22 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS