Hayward HPC4-ACT-AQC ECOMMAND-4-Operation-Manual-092420ARevF - Page 9

Settings Menu

Page 9 highlights

Settings Menu The Settings Menu allows you to set all system operating parameters except the timeclock and countdown timers which are part of the Timers Menu. Spa Heater1 Off Adjust the desired spa temperature (Off, 65°F, 66°F, ...103°F, 104°F, Off) Move to previous/next menu item The spa heater setting will only appear if the system has been set up for "spa only" or "pool and spa" operation and the heater control is enabled. The heater will turn on whenever the pool/spa valves are in the "spa only" position and the filter pump is running and the spa water temperature is less than the desired temperature setting. If you have both solar heat and a conventional heater and the solar priority option is selected (Configuration Menu), then the conventional heater will only operate when solar heat is NOT available. Pool Heater1 Off Adjust the desired pool temperature (Off, 65°F, 66°F, ...103°F, 104°F, Off) Move to previous/next menu item The pool heater setting will only appear if the system has been set up for "pool only" or "pool and spa" operation and the heater control is enabled. The heater will turn on whenever the pool/spa valves are in the "pool only" or "spa spillover" position and the filter pump is running and the pool water temperature is less than the desired temperature setting. If you have both solar heat and a conventional heater and the solar priority option is selected (Configuration Menu), then the conventional heater will only operate when solar heat is NOT available. Spa Solar 102°F Adjust the desired spa temperature (Off, 65°F, 66°F, ...103°F, 104°F, Off) Move to previous/next menu item The spa solar setting will only appear if the system has been set up for "spa only" or "pool and spa" operation and the solar control is enabled. The solar system will turn on whenever the pool/spa valves are in the "spa only" position, the filter pump is running, the spa water temperature is less than the desired temperature setting, and solar heat is available. Pool Solar 88°F Adjust the desired pool temperature (Off, 65°F, 66°F, ...103°F, 104°F, Off) Move to previous/next menu item The pool solar setting will only appear if the system has been set up for "pool only" or "pool and spa" operation and the solar control is enabled. The solar system will turn on whenever the pool/spa valves are in the "pool only" or "spa spillover" position, the filter pump is running, the pool water temperature is less than the desired temperature setting, and solar heat is available. 8 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
8
Settings Menu
The Settings Menu allows you to set all system operating parameters except the timeclock and
countdown timers which are part of the Timers Menu.
The spa heater setting will only appear if the system has been set up for “spa only”
or “pool and spa” operation and the heater control is enabled.
The heater will turn
on whenever the pool/spa valves are in the “spa only” position and the filter pump is
running and the spa water temperature is less than the desired
temperature setting.
If you have both solar heat and a conventional heater and the solar priority option is
selected (Configuration Menu), then the conventional heater will only operate when
solar heat is NOT available.
The pool heater setting will only appear if the system has been set up for “pool only”
or “pool and spa” operation and the heater control is enabled.
The heater will turn on
whenever the pool/spa valves are in the “pool only” or “spa spillover” position and the
filter pump is running and the pool water temperature is less than the desired tempera-
ture setting.
If you have both solar heat and a conventional heater and the solar priority
option is selected (Configuration Menu), then the conventional heater will only operate
when solar heat is NOT available.
The spa solar setting will only appear if the system has been set up for “spa only” or
“pool and spa” operation and the solar control is enabled.
The solar system will turn on
whenever the pool/spa valves are in the “spa only” position, the filter pump is running,
the spa water temperature is less than the desired temperature setting, and solar heat
is available.
The pool solar setting will only appear if the system has been set up for “pool only” or
“pool and spa” operation and the solar control is enabled.
The solar system will turn
on whenever the pool/spa valves are in the “pool only” or “spa spillover” position, the
filter pump is running, the pool water temperature is less than the desired temperature
setting, and solar heat is available.
Spa Heater1
Off
Adjust the desired spa temperature (Off, 65°F, 66°F, ...103°F, 104°F, Off)
Move to previous/next menu item
Pool Heater1
Off
Adjust the desired pool temperature (Off, 65°F, 66°F, ...103°F, 104°F, Off)
Move to previous/next menu item
Spa Solar
102°F
Adjust the desired spa temperature (Off, 65°F, 66°F, ...103°F, 104°F, Off)
Move to previous/next menu item
Pool Solar
88°F
Adjust the desired pool temperature (Off, 65°F, 66°F, ...103°F, 104°F, Off)
Move to previous/next menu item