Hayward HYDRAPURE HydraPure Owners Manual - Page 14

Ozone Lamps Replacement

Page 14 highlights

6 C arefully lift the lamp assembly, including lamp holder, do not pull excessively on the lamp wires. 7 I nsert lamps into lamp holder. Lamps must be aligned and seated securely in the lamp holder. Roll the black O-rings up onto the ceramic end of lamp from position A to B. B 8 G ently insert lamps into the A lower lamp retainer and lower lamp assembly into unit. Re-install the spring clip and re-attach the lamp connectors to the ballast. 9 A fter power is restored, press and hold UV BULB LIFE Button, for a minimum of 15 seconds, to reset the lamp life indicator. Discard lamp(s) appropriately. Visit www.lamprecycle.org for instructions on disposal. Ozone Lamps Replacement WARNING: Turn off all power to the HydraPure unit and pool pump. Before proceeding allow at least 15 minutes for the lamp(s) in the unit to cool. Never remove the electrical enclosure cover without first disconnecting the power source from the HydraPure unit. Never remove the HydraPure unit's cover without turning off the pump. Before removing lamps, you must wear protective rubber gloves and safety eye wear. Do not handle a hot lamp or serious burns will occur. Red flashing OZONE BULB LIFE indicates ozone bulb no longer producing ozone and should be replaced soon. 13 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

7
Insert lamps into lamp holder.
Lamps must be aligned and
seated securely in the lamp
holder. Roll the black O-rings
up onto the ceramic end of
lamp from position A to B.
8
Gently insert lamps into the
lower lamp retainer and
lower lamp assembly into unit.
Re-install the spring clip and
re-attach the lamp connectors
to the ballast.
9
After power is restored, press
and hold UV BULB LIFE Button,
for a minimum of 15 seconds,
to reset the lamp life indicator.
Discard lamp(s) appropriately. Visit
www.lamprecycle.org for instruc-
tions on disposal.
A
B
Red flashing OZONE BULB LIFE indicates ozone bulb no
longer producing ozone and should be replaced soon.
Ozone Lamps Replacement
WARNING:
Turn off all power to the HydraPure unit and pool pump. Before proceeding allow at least
15 minutes for the lamp(s) in the unit to cool. Never remove the electrical enclosure cover without first
disconnecting the power source from the HydraPure unit. Never remove the HydraPure unit’s cover
without turning off the pump. Before removing lamps, you must wear protective rubber gloves and
safety eye wear. Do not handle a hot lamp or serious burns will occur.
6
Carefully lift the lamp
assembly, including
lamp holder, do not
pull excessively on the
lamp wires.
13
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS