Hayward HYDRAPURE HydraPure Owners Manual - Page 14
Ozone Lamps Replacement
View all Hayward HYDRAPURE manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 14 highlights
6 C arefully lift the lamp assembly, including lamp holder, do not pull excessively on the lamp wires. 7 I nsert lamps into lamp holder. Lamps must be aligned and seated securely in the lamp holder. Roll the black O-rings up onto the ceramic end of lamp from position A to B. B 8 G ently insert lamps into the A lower lamp retainer and lower lamp assembly into unit. Re-install the spring clip and re-attach the lamp connectors to the ballast. 9 A fter power is restored, press and hold UV BULB LIFE Button, for a minimum of 15 seconds, to reset the lamp life indicator. Discard lamp(s) appropriately. Visit www.lamprecycle.org for instructions on disposal. Ozone Lamps Replacement WARNING: Turn off all power to the HydraPure unit and pool pump. Before proceeding allow at least 15 minutes for the lamp(s) in the unit to cool. Never remove the electrical enclosure cover without first disconnecting the power source from the HydraPure unit. Never remove the HydraPure unit's cover without turning off the pump. Before removing lamps, you must wear protective rubber gloves and safety eye wear. Do not handle a hot lamp or serious burns will occur. Red flashing OZONE BULB LIFE indicates ozone bulb no longer producing ozone and should be replaced soon. 13 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS