NorthStar™ Pump Series Product Specifications Page 5 of 15 HP 3/4 1 1 1/2 2 2 1/2 3 FR "A" 13 1/4" 13 1/2" 14" 14 3/4" N/A 16 1/4" MR "A" N/A 13 1/4" 13 1/2" 14" 14 3/4" 16 1/4" FR: Full Rate MR: Max Rate Installation Instructions WARNING - This product should be installed and serviced only by a qualified professional. Pump Location Locate pump as close to pool as practical and run suction lines as direct as possible to reduce friction loss. Suction lines should have continuous slope upward from lowest point in line. Joints must be tight (but not over-tightened). Suction line diameter must equal or be larger than the discharge line diameter. Though the pump is designed for outdoor use, it is strongly advised to place pump and filter in the shade to shield them from continuous direct heat. Select a well-drained area that will not flood when it rains. Do NOT install pump and filter in a damp or non-ventilated location. Keep motor clean. Pump motors require free circulation of air for cooling. Pump Mounting Install pump on a level concrete slab or other rigid base to meet all local and national codes. Pump may be secured with screws or bolts to further reduce vibration and stress on pipe or hose joints. The base must be level, rigid, and vibration free. Pump mount must: Allow pump inlet height to be as close to water level as possible. Allow use of short, direct suction pipe (to reduce friction losses). Allow for gate valves in suction and discharge piping. Be protected from excess moisture and flooding. Allow adequate access for servicing pump and piping. Pipe Sizing Chart Pipe Size [mm] 1" [32] MAXIMUM RECOMMENDED SYSTEM FLOW RATE BY PIPE SIZE Flow Rate Suction Pipe Pipe Size Flow Rate Suction Pipe Pipe Size Flow Rate GPM [LPM] Length * [mm] GPM [LPM] Length * [mm] GPM [LPM] 20 [75] 5" 1 ½" [50] 45 [170] 7 ½" 2 ½" [75] 110 [415] Suction Pipe Length * 12 ½" 1 ¼" [40] 30 [110] 6 ¼" 2" [63] 80 [300] 10" 3" [90] 160 [600] 15" * NOTE - It is recommended that a minimum length of straight piping (shown as "L" in above diagram), equivalent to 5 pipe size diameters, be used between the pump suction inlet and any plumbing fittings (elbows, valves, etc.). WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15

NorthStar
Pump Series__________________
____________________________Page 5 of 15
WWW.HAYWARDPOOL.COM
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Product Specifications
Installation Instructions
WARNING –
This product should be installed and serviced only by a qualified professional.
Pump Location
Locate pump as close to pool as practical and run suction lines as direct as possible to reduce friction
loss.
Suction lines should have continuous slope upward from lowest point in line.
Joints must be tight
(but not over-tightened).
Suction line diameter must equal or be larger than the discharge line diameter.
Though the pump is designed for outdoor use, it is strongly advised to place pump and filter in the
shade to shield them from continuous direct heat.
Select a well-drained area that will not flood when it rains.
Do NOT
install pump and filter in a damp or non-ventilated location.
Keep motor clean.
Pump motors require free circulation of
air for cooling.
Pump Mounting
Install pump on a level concrete slab or other rigid base to meet all local and national codes.
Pump may be secured with
screws or bolts to further reduce vibration and stress on pipe or hose joints.
The base must be level, rigid, and vibration free.
Pump mount must:
±
Allow pump inlet height to be as close to water level as possible.
±
Allow use of short, direct suction pipe (to reduce friction losses).
±
Allow for gate valves in suction and discharge piping.
±
Be protected from excess moisture and flooding.
±
Allow adequate access for servicing pump and piping.
Pipe Sizing Chart
* NOTE -
It is recommended that a minimum length of straight piping (shown as “L” in above diagram), equivalent
to 5 pipe size diameters, be used between the pump suction inlet and any plumbing fittings (elbows, valves, etc.).
HP
FR “A”
MR “A”
3/4
13 1/4”
N/A
1
13 1/2”
13 1/4”
1 1/2
14”
13 1/2”
2
14 3/4”
14”
2 1/2
N/A
14 3/4”
3
16 1/4”
16 1/4”
MAXIMUM RECOMMENDED SYSTEM FLOW RATE BY PIPE SIZE
Pipe Size
[mm]
Flow Rate
GPM [LPM]
Suction Pipe
Length *
Pipe Size
[mm]
Flow Rate
GPM [LPM]
Suction Pipe
Length *
Pipe Size
[mm]
Flow Rate
GPM [LPM]
Suction Pipe
Length *
1”
[32]
20
[75]
5”
1 ½”
[50]
45
[170]
7 ½”
2 ½”
[75]
110
[415]
12 ½”
1 ¼”
[40]
30
[110]
6 ¼”
2”
[63]
80
[300]
10”
3”
[90]
160
[600]
15”
FR:
Full Rate
MR:
Max Rate