Hayward SwimClear™ Models: C2025 C3025 C4025 C5025 C7000 - Page 2

Swimclear Cartridge Filter, Isc2028 Rev C - swimclear cartridge filter manual

Page 2 highlights

Page 2 of 12 SWIMCLEAR CARTRIDGE FILTER ISC2028 REV C This is the safety-alert symbol. When you see this symbol on your equipment or in this manual, look for one of the following signal words and be alert to the potential for personal injury or death. WARNING Warns about hazards that could cause serious personal injury or, death, and or major property damage and if ignored presents a potential hazard. CAUTION Warns about hazards that will or can cause minor or moderate personal injury and/or property damage and if ignored presents a potential hazard. It can also make consumers aware of actions that are unpredictable and unsafe. The NOTICE label indicates special instructions that are important but not related to hazards. READ, UNDERSTAND, AND FOLLOW ALL SAFETY AND OPERATION INSTRUCTIONS. FAILURE TO FOLLOW SAFETY AND OPERATION INSTRUCTIONS CAN RESULT IN SEVERE PERSONAL INJURY OR DEATH. CAUTION To reduce risk of injury, do not permit children to use or climb on this product. Closely supervise children at all times. The ANSI/NSPI-4 Standard (above-ground and on-ground pools) advises that components such as the filtration system, pumps, and heaters be positioned to prevent their being used as a means of access to the pool by young children. WARNING COMPONENT SEPARATION HAZARD Pool and spa water circulation systems operate under hazardous pressure during start up, normal operation, and possibly after pump shut off. Pressure in system can cause explosive component separation of the upper filter body if safety and operation instructions are not followed. Severe personal injury or death can result. This product should be installed and serviced only by a qualified pool professional. TO AVOID COMPONENT SEPARATION • Follow all safety and operation instructions. • Do not operate water circulation system if a system component is assembled improperly, damaged, missing, or not a genuine Hayward component. • Before performing maintenance on the water circulation system, verify all system and pump controls are in OFF position and filter manual air relief valve is in the OPEN position. • Use ONLY Hayward clamp system components: DEX2421JKIT clamp assembly, DEX2421J2 nut/bolt assembly, and a DEX2422Z2 metal reinforced seal. Non-Hayward components may fail in use and cause explosive separation. • Never rely on hand tightening the clamp nut to the clamp bolt. Using a ¾" socket on a torque wrench, torque clamp nut and clamp bolt to 150 inch-lbs. • Before starting system pump, insure filter manual air relief valve body is in LOCK position in filter upper body. • Before starting the system pump, verify that all system valves are set in a position to allow water from the filter to return back to the pool. • Before starting the system pump, the manual air relief valve must be in the OPEN position. • When starting pump, do not stand over or near filter. • If water leakage appears in the area of the filter tank clamp, immediately turn off all system circulation pumps and electrical power. Do not return to the filter until all water flow has stopped. Reassemble the clamp system per the instructions in this owner's manual to stop the leak. • Return to filter to close manual air relief valve only when a steady stream of water (Not air or air and water mix) is discharged from the manual air relief valve. • Do not change filter control valve position while system pump is running. WARNING EXCESS PRESSURE HAZARD Pressure testing of the pump and filter system in excess of the 50 PSI can cause explosive separation of the components. Component separation can result in severe personal injury or death. WARNING ELECTROCUTION HAZARD High Voltage electricity is present in the pool and spa equipment. High voltage electricity can cause shock and electrocution. Shock and electrocution can result in severe personal injury or death. • All electrical wiring MUST be in conformance with applicable local codes, regulations and the National Electrical Code (NEC). • Before performing any service or maintenance on electrical equipment turn off all electrical power. • Contact a licensed electrician or building inspector for information on local electrical codes for bonding requirements. • Verify water discharge from the filter manual air relief valve is directed away from electrical devices. • Do not locate pump controls over or near filter. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12

Page 2 of 12
SWIMCLEAR CARTRIDGE FILTER
ISC2028 REV C
READ, UNDERSTAND, AND FOLLOW ALL SAFETY AND OPERATION
INSTRUCTIONS.
FAILURE TO FOLLOW SAFETY AND OPERATION INSTRUCTIONS CAN RESULT
IN SEVERE PERSONAL INJURY OR DEATH.
CAUTION
To reduce risk of injury, do not permit children to use or climb on this product.
Closely
supervise children at all times.
The ANSI/NSPI-4 Standard (above-ground and on-ground pools) advises that
components such as the filtration system, pumps, and heaters be positioned to prevent their being used as a
means of access to the pool by young children.
WARNING
COMPONENT SEPARATION HAZARD
Pool and spa water circulation systems operate under hazardous pressure during start up, normal
operation, and possibly after pump shut off.
Pressure in system can cause explosive component
separation of the upper filter body if safety and operation instructions are not followed.
Severe
personal injury or death can result.
This product should be installed and serviced only by a qualified pool professional.
TO AVOID COMPONENT SEPARATION
Follow all safety and operation instructions.
Do not operate water circulation system if a system component is assembled improperly, damaged, missing, or not a
genuine Hayward component.
Before performing maintenance on the water circulation system, verify all system and pump controls are in OFF position
and filter manual air relief valve is in the OPEN position.
Use ONLY Hayward clamp system components: DEX2421JKIT clamp assembly, DEX2421J2 nut/bolt assembly, and a
DEX2422Z2 metal reinforced seal.
Non-Hayward components may fail in use and cause explosive separation.
Never rely on hand tightening the clamp nut to the clamp bolt.
Using a ¾” socket on a torque wrench, torque clamp nut
and clamp bolt to 150 inch-lbs.
Before starting system pump, insure filter manual air relief valve body is in LOCK position in filter upper body.
Before starting the system pump, verify that all system valves are set in a position to allow water from the filter to return
back to the pool.
Before starting the system pump, the manual air relief valve must be in the OPEN position.
When starting pump, do not stand over or near filter.
If water leakage appears in the area of the filter tank clamp, immediately turn off all system circulation pumps and
electrical power.
Do not return to the filter until all water flow has stopped.
Reassemble the clamp system per the
instructions in this owner’s manual to stop the leak.
Return to filter to close manual air relief valve only when a steady stream of water (Not air or air and water mix) is
discharged from the manual air relief valve.
Do not change filter control valve position while system pump is running.
WARNING
EXCESS PRESSURE HAZARD
Pressure testing of the pump and filter system in excess of the 50 PSI can cause explosive separation
of the components.
Component separation can result in severe personal injury or death.
WARNING
ELECTROCUTION HAZARD
High Voltage electricity is present in the pool and spa equipment.
High voltage electricity can cause
shock and electrocution.
Shock and electrocution can result in severe personal injury or death.
All electrical wiring MUST be in conformance with applicable local codes, regulations and the
National Electrical Code (NEC).
Before performing any service or maintenance on electrical equipment turn off all electrical power.
Contact a licensed electrician or building inspector for information on local electrical codes for bonding requirements.
Verify water discharge from the filter manual air relief valve is directed away from electrical devices.
Do not locate pump controls over or near filter.
This is the safety-alert symbol. When you see this symbol on your equipment or in this manual, look for one of the
following signal words and be alert to the potential for personal injury or death.
WARNING
Warns about hazards that
could
cause serious personal injury or, death, and or major property
damage and if ignored presents a potential hazard.
CAUTION
Warns about hazards that
will
or
can
cause minor or moderate personal injury and/or property damage
and if ignored presents a potential hazard.
It can also make consumers aware of actions that are unpredictable and unsafe.
The
NOTICE
label indicates special instructions that are important but not related to hazards.
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS