Hayward TracVac TracVac Owners Manual - Page 4

Installation

Page 4 highlights

Installation IMPORTANT: Pools with Variable Speed Pumps - The cleaner requires a minimum & maximum rate of flow to operate optimally. If the variable speed pump has multiple speeds programmed, use the Flow Gauge to calibrate the recommended flow rate at the pump's highest programmed speed. This can be done by the using the Flow Regulator Valve and adjusting pump speed manually to attain the correct flow at the highest preset speed. See page 5 for more information. By using the highest preset speed, you'll ensure that all other settings will never exceed the recommended maximum flow rate. IMPORTANT: Pools with Solar Heating - Solar Heating must be turned OFF whenever the TracVac is in use. If using Solar Heating and the TracVac, always alternate schedules. Pool Preparation Manually remove very large and excessive debris from pool (ie. post- storm, spring cleaning/pool opening situations). Perform a backwash or clean filter cartidges, clean your filter, skimmer baskets and pump basket. Check that chemical balance is correct. If not, take the time to correct it before using the TracVac. If you chemically shock the pool, wait 1-2 days before continuing. Point all your return fittings downward to maximize cleaner pool coverage. 3 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16

Installation
IMPO
RTANT: Pools with Variable Speed Pumps
- The cleaner requires a minimum & maximum
rate of flow to operate optimally. If the variable speed pump has multiple speeds programmed, use
the Flow Gauge to calibrate the recommended flow rate at the pump’s highest programmed speed.
This can be done by the using the Flow Regulator Valve and adjusting pump speed manually to
attain the correct flow at the highest preset speed. See page 5 for more information. By using the
highest preset speed, you'll ensure that all other settings will never exceed the recommended
maximum flow rate.
IMPORTANT: Pools with Solar Heating
- Solar Heating must be turned OFF whenever the Trac-
Vac is in use. If using Solar Heating and the TracVac, always alternate schedules.
Pool Preparation
Manually remove very large and excessive debris from pool
(ie. post- storm, spring cleaning/pool opening situations).
Perform a backwash or clean filter cartidges, clean your
filter, skimmer baskets and pump basket.
Check that chemical balance is correct. If not, take the time
to correct it before using the TracVac. If you chemically
shock the pool, wait 1-2 days before continuing.
Point all your return fittings downward to maximize cleaner
pool coverage.
3
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS