Hayward VR1000 Model: All Models - Service/Installation - Page 17

Run & Record Sheet

Page 17 highlights

Page 17 of 24 STRATUM™ Model VR1000 P/N: ISVR1000TECH Rev: J RUN & RECORD SHEET: (See page 8) Run in pool and spa mode with valves in normal configuration, all the skimmers open, to determine the lowest and highest operating vacuums with a CLEAN filter. NOTE: If the vacuum levels do not change when the valves are changed, the saddle position should be checked to assure that the vacuum pick-up of the STRATUM is in the correct location relative to the pump suction inlet. (See Figure 1 and Illustrations below) Pump Operating in: Stable Vacuum in Unprotected Mode POOL Mode Fully open suction through Main Drains & Open Skimmers.......... ________ Dedicated Suction Lines Closed Heater bypass fully open All pool returns/water features fully open SPA Mode Fully open suction through Main Drains & Open Skimmers.......... Heater bypass fully open All spa returns/water features fully open ________ Add 5" to higher non-blocked recorded suction value to be used as the "High Vac Value" (Page 14). If possible check to assure the fully blocked suction is above the "High Vac Value". Correct Installation of Saddle Fitting No valves between the pump and the saddle fitting . PUMP SADDLE FITTING Do Not Install the Saddle fitting in the positions marked with an X. There would be a valve between the pump and the saddle fitting. VALVE X X X USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Pomona, CA Clemmons, NC Nashville, TN Tel: 908.351.5400 www.haywardpool.com

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

Page 17 of 24
STRATUM™ Model VR1000
P/N: ISVR1000TECH
Rev: J
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Pomona, CA
Clemmons, NC
Nashville, TN
Tel: 908.351.5400
www.haywardpool.com
RUN & RECORD SHEET:
(See page 8)
Run in pool and spa mode with valves in normal configuration, all the skimmers open, to determine the lowest and highest
operating vacuums with a
CLEAN
filter.
NOTE:
If the vacuum levels do not change when the valves are changed, the saddle position should be checked to assure
that the vacuum pick-up of the STRATUM is in the correct location relative to the pump suction inlet.
(See Figure 1 and
Illustrations below)
Pump Operating in:
POOL Mode
Fully open suction through Main Drains & Open Skimmers……….
Dedicated Suction Lines Closed
Heater bypass fully open
All pool returns/water features fully open
SPA Mode
Fully open suction through Main Drains & Open Skimmers……….
Heater bypass fully open
All spa returns/water features fully open
Add 5” to higher non-blocked recorded suction value to be used as the “High Vac Value” (Page 14)
.
If possible check to assure the fully blocked suction is above the “High Vac Value”.
Stable Vacuum in
Unprotected Mode
________
________
Correct Installation of Saddle Fitting
No valves between the pump and the
saddle fitting
.
Do Not Install the Saddle fitting in the
positions marked with an X.
There
would be a valve between the pump and
the saddle fitting.
PUMP
SADDLE
FITTING
VALVE
X
X
X