Page 21 of 24 STRATUM™ Model VR1000 P/N: ISVR1000TECH Rev: J ET = 19 ET = 20 ET = 21 ET = 22 ET = 23 ET = 24 ET = 25 ET = 26 ET = 27 ET = 30 ET = 31 ET = 32 ET = 33 ET = 34 ET = 35 ET = 36 ET = 37 Menu key pressed in timer off loop Stabilization - Stop switch Stabilization - Hi spike, 2 parms in 16 bit ADC units - Hi Spike Threshold & actual trigger value Stabilization - Run dry Stabilization - No stabilization - 5 tries Menu key pushed in stabilization Stabilized in. Hg less than stabilization threshold which was determined at 1st Stab. time. 2 parms, 16 bits ADC units - stab & threshold values Timer Override by Yes & No key press while pumps were turned off by the timer. Pumps will run in this mode for about 2 hours. Operator has indicated status of the drain cover. First 8 bit parm = 0 - operator says cover is NOT installed, 1 --- it IS installed. This occurs in the Pool Tech Mode procedures. Run - Stop switch RUN - Rate of change error, vacuum rising too fast 2 parms in 8 bit ADC units - difference threshold and actual difference detected Run - detected pinched vacuum hose. 3 - 16 bit ADC value parms: Before vent, after vent, difference threshold Run - Hi vacuum (window), 2 parms in 16 bit ADC units - Hi window threshold & actual trigger value detected Run - Lo vacuum (window), 2 parms in 16 bit ADC units - Hi window threshold & actual trigger value detected Run - periodic SS test initiated Run - Sensor/Solenoid failure (periodic test) Run - possible pinched vacuum hose, test to see if it is (run a test similar to periodic SS test). (1) 8 bit parm - difference in ADC units (Hi - Lo) (Pinch Count) readings. Note that 2 or less is a possible pinched line and further testing is done. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Pomona, CA Clemmons, NC Nashville, TN Tel: 908.351.5400 www.haywardpool.com

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

Page 21 of 24
STRATUMâ„¢ Model VR1000
P/N: ISVR1000TECH
Rev: J
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Pomona, CA
Clemmons, NC
Nashville, TN
Tel: 908.351.5400
www.haywardpool.com
ET = 19
Menu key pressed in timer off loop
ET = 20
Stabilization - Stop switch
ET = 21
Stabilization - Hi spike, 2 parms in 16 bit ADC units - Hi Spike Threshold & actual trigger value
ET = 22
Stabilization - Run dry
ET = 23
Stabilization - No stabilization - 5 tries
ET = 24
Menu key pushed in stabilization
ET = 25
Stabilized in. Hg less than stabilization threshold which was determined at 1st Stab. time.
2 parms, 16 bits ADC units - stab & threshold values
ET = 26
Timer Override by Yes & No key press while pumps were turned off by the timer. Pumps will
run in this mode for about 2 hours.
ET = 27
Operator has indicated status of the drain cover. First 8 bit parm = 0 - operator says cover is
NOT installed, 1 --- it IS installed. This occurs in the Pool Tech Mode procedures.
ET = 30
Run - Stop switch
ET = 31
RUN - Rate of change error, vacuum rising too fast 2 parms in 8 bit ADC units - difference
threshold and actual difference detected
ET = 32
Run - detected pinched vacuum hose. 3 - 16 bit ADC value parms: Before vent, after vent,
difference threshold
ET =
33
Run - Hi vacuum (window), 2 parms in 16 bit ADC units - Hi window threshold & actual trigger
value detected
ET =
34
Run - Lo vacuum (window), 2 parms in 16 bit ADC units - Hi window threshold & actual trigger
value detected
ET = 35
Run - periodic SS test initiated
ET = 36
Run - Sensor/Solenoid failure (periodic test)
ET = 37
Run - possible pinched vacuum hose, test to see if it is (run a test similar to periodic SS test). (1)
8 bit parm - difference in ADC units (Hi - Lo) (Pinch Count) readings. Note that 2 or less is a
possible pinched line and further testing is done.