Hayward VR1000 Model: All Models - Service/Installation - Page 20
Low AC voltage detected, 3 - 16 bit ADC values: Actual value, Low Limit and High Limit
View all Hayward VR1000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 20 highlights
Page 20 of 24 RECORDED CODES STRATUM™ Model VR1000 P/N: ISVR1000TECH Rev: J ET = 1 Low AC voltage detected, 3 - 16 bit ADC values: Actual value, Low Limit and High Limit ET = 2 High AC voltage detected, 3 - 16 bit ADC values: Actual value, Low Limit and High Limit ET = 3 Low AC voltage detected, 3 - 16 bit ADC values: Actual value, Low Limit and High Limit ET = 4 High AC voltage detected, 3 - 16 bit ADC values: Actual value, Low Limit and High Limit ET = 5 Power on; 6 parms - Zero value (2 bytes), Hi spike value (2 bytes), Difference value (1 byte in ADC units), The following 3 will be 0 when DIP sw is ON. DIP 3 (2 speed pump en/dis - 1 byte), DIP 4 (timer en/dis - 1 byte), DIP 6 (Booster pump en/dis - 1 byte) ET = 6 OnHour, OnMin, OffHour & OffMin byte values in E1 - E4 vars. This entry won't be found if thetimer is DISABLED with the DIP switch 2. This entry indicates system was started because the current time moved inside the timer window. ET = 7 OnHour, OnMin, OffHour & OffMin byte values in E1 - E4 vars. This entry won't be found if thetimer is DISABLED with the DIP switch 2. This entry indicates system was stopped because the current time moved outside the timer window. ET = 8 The time and date have been changed to the time and date of this entry. ET = 9 Low speed pump turned ON by timer. (2) 8 bit Parms - On hour followed by On minute ET = 10 Pulsing - Stop switch ET = 11 Pulsing - Hi Spike, 2 parms in 16 bit ADC units - Hi Spike Threshold And actual trigger value ET = 12 Pulsing - Sensor/Solenoid failure - didn't see at least 1/2 in Hg difference during pulsing, 3 parms in ADC units - highest & values and 1/2 in Hg ET = 13 Pulsing - No Pump Prime failure - wouldn't draw a prime after trying for 'nn' minutes ET = 14 Menu key pushed in startup pulsing ET = 15 Booster Pump turned ON by timer. (4) 8 bit parms-On Min & Sec followed by Off Min & Sec ET = 16 Booster Pump turned OFF by timer. (4) 8 bit parms- On Min & Sec followed by Off Min & Sec ET = 17 Spare switch closure detected, run pump in high speed mode continuously. ET = 18 Spare switch opening after above closure detected, return to normal operation USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Pomona, CA Clemmons, NC Nashville, TN Tel: 908.351.5400 www.haywardpool.com