Bonding, Pump Output, Electrolytic Cell and Flow Switch

Page 14 highlights

Bonding A lug used for bonding is attached to the bottom of the AquaTrol enclosure. Connect to the pool bonding system using minimum 8AWG copper wire if required by code. Pump Output The AquaTrol's filter pump output is rated at 120 VAC, 15 A max. Check the electrical rating marked on the pump motor. Connecting a pump with a higher amperage rating may result in permanent damage to the AquaTrol. The 120 VAC standard or twist lock pump receptacle is located outside, on the bottom of the enclosure. Electrolytic Cell and Flow Switch The cell and flow switch plug into connectors on the AquaTrol electronics unit. Note that return jet units (-RJ option) will NOT have a flow switch. See diagram below. 12 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
12
Bonding
A lug used for bonding is attached to the bottom of the AquaTrol enclosure.
Connect to the pool
bonding system using minimum 8AWG copper wire if required by code.
Pump Output
The AquaTrol’s filter pump output is rated at 120 VAC, 15 A max.
Check the electrical rating marked
on the pump motor.
Connecting a pump with a higher amperage rating may result in permanent
damage to the AquaTrol.
The 120 VAC standard or twist lock pump receptacle is located outside, on
the bottom of the enclosure.
Electrolytic Cell and Flow Switch
The cell and flow switch plug into connectors on the AquaTrol electronics unit.
Note that
return jet
units (-RJ option) will NOT have a flow switch.